EloStar Master 3X0 / 4X0 / - smart
Operation
Manual V.1.03H
69
7.12.9
Closing a Lock
Closing a lock after OTC input has not been evaluated by UL.
Settings
The bolt work contact does not actively prevent lock
closure. Via software PC software
, the option ‘Manual
closing with code query’ has not been selected.
1.
Press key
Clear
and release it after a second.
Open
is on display.
2.
With key
<
or
>
select
Close
and press key
Enter
.
Close
and, as the case may be,
Lock 1
are on display
3.
With key
<
or
>
select the lock, if necessary, and press
Enter.
Close | Please wait
is on display. The lock bolt engages.
Close | Lock closed no.
is on display.
You have successfully closed a lock.
7.12.10
Closing a Lock with Code Input
In order to close a lock by entering code, either PIN- or card code
(TwinCard code access) is sufficient.
Settings
Via software TwinComm USB, option ‘Manual
closing with code query’ has been selected.
Boxes
Release
,
Close & code
,
PIN code
or
Card
of the user matrix have been marked for you.
1.
Press key
Enter
and release it after a second.
The system checks its status. Date and time are on display.
2.
With key
<
or
>
select
Close
and key
Enter
.
Close
and, with a system with 2 or 3 locks,
Lock 1
are on display.
3.
If required, select the lock with menu key
<
or
>
and press
Enter
.
Code entry | User: Master
is on display.
4.
Present your user identification data.
Also see
‘User- / Personnel Numbers’ on page 51.
User No | PIN code
is on display.
5.
Select
PIN-Code
or
Code card
and enter code or insert card.
See the instructions ‘Open a Lock by …’ at the beginning of this chapter.
Close
| Please wait
is on display. The lock bolt engages.
Close | Lock closed no.
is on display.
You have successfully closed a lock.
7.12.11
Closing Automatically with the Door Switch
This option can be set via optional software.
Settings
The bolt work switch is not in a position in which it prevents
automatic closing.
•
Close the door of the safe / box / container.
Via regular checks on the state of door- and bolt switches, the system registers
that the door has been closed and the system closes the locks automatically.
The lock has closed automatically.