EloStar Master 3X0 / 4X0 / - smart
Assembly
Manual V.1.03H
39
Fig. 27: Dimensions of the lock 400 (bolt stroke 8.5-15 mm)
Caution
Distortion (caused by uneven surface of the part the lock
is attached to) may cause malfunctions.
Mount the lock attaching it to a plain, even, flush surface.
2.
Insert the 4 screws into the bores of the lock.
Caution
Exerting too much force may cause malfunction of the
lock.
Fasten the screws with a maximum torque of
5 Nm
.
3.
Fasten the 4 screws to the fastening points in the safe.
4.
Make sure that lock and bolt are mounted tension-free.
You have fastened the lock successfully.
5.5.2
Connecting the Lock
Take
1 cable 4-core with JST plugs, 1 cable 6-core with JST plugs and 2 cables
6-core with JST plugs and RJ11C/RJ-11W plugs.
1.
Connect a bus cable (4-core) from socket A of the operating unit to socket Flat A
of EloXT II
(„Flat A“ in fig. „Connections EloXT II“, p.24).
Fig. 28: 2.
Connect a further cable (6-core) from JST socket for IO-functions
(FlatControl: item 4 of fig
. „Connections FlatControl“, p.36,
QPad: item 4 of
fig. „Terminals of QPad“, p. 33)
t
o socket „Flat IO“ of EloXT II („Flat IO“ in fig. „Connections EloXT II“, S.24.
3.
Connect EloXT II socket „Lock 1(1/A)“ via cable (6-core) with lock socket A and
connect EloXT II socket
„Lock 1(2/B)“ via cable (6-core) with lock socket B.
In case there is a second lock in the system, connect EloXT II socket
„Lock
2(1/A)“ with lock socket A and with a further 6-core cable connect EloXT II socket
„Lock 2(2/B)“ with lock socket B.
4.
Make sure the connection clips snap into place.