EloStar Master 3X0 / 4X0 / - smart
System Description
Manual V.1.03H
15
Additional, independent CIT user range administrated separately
with selectable user group authorisation for opening
Display of service phone number along with error message display
Additional functions with QPadComm
(not evaluated by UL)
No chip cards, but configuration via Mini USB / Bluetooth
10,000 entries event protocol
3.3.3
Optional Functions with Version EM11 and higher
This firmware version is compatible to FlatControl only. If not indicated otherwise, the
functions are available also for systems with QPad. The version of the firmware can be
displayed via menu
Status / Info
. See page 92. Some of these functions can be
programmed with the optional PC software QPadComm / TwinComm.
User numbers can be replaced by personnel numbers
Locally (via user matrix in PC software), you can configure the system in such a way that
all users are not required to enter user numbers assigned to them within the lock system
only but personnel numbers which may consist of 3, 4, 5 or 6 digits.
Integration MIFARE RFID
Available with hardware Flat006 or higher with RFID module only. Locally via PC
software
(via tab „Settings“, field „Code card“ in TwinComm, for example, you can
configure the system in such a way that all users are not required to use smart cards
„TwinCard code access“ but contactless MIFARE RFID tags.
Users open with single-use-code
Locally (via user matrix in PC software), you can configure the system in such a way that
selected users have to enter 6-digit single-use-code (OTC) in order to open the lock.
With this option selected for users, these users have to enter the following items in order
to open in the following way (and in the order given below):
User- / personnel number -> PIN code / smart card -> single-use-code
or
RFID tag / -card -> PIN code / smart card -> single-use-code
Users can be made temporary masters, and as such they can register new
users, new PIN code and code cards
Function not UL evaluated. Locally via PC software
(via tab „Settings“, tab sector „CIT
(
WTU)”, field „Master (temp.)“ in TwinComm, for example), you can configure the system
in such a way that selected users will be able to register a new user after entering 6-digit
single-use-code. See above for information on the correct sequence of the code input.
FlatControl: With the lock open, after activating FlatControl by pressing any key, you can
start triggering this function by pressing an arrow key and key F1 at the operating unit.
QPad: With the lock open, after activating QPad by pressing any key, start triggering this
function by selecting the hidden menu and there selecting
sub menu “New user code”.
Upon successful registration of a new user, a valid return code is on display at the
operating unit. Display the latest valid return code with menu
„Status / Info“.
Operation with two operating units FlatControl
The lock system can be operated with two operating units. Configuration takes place
during the commissioning. The VdS approval also covers the operation with two
operating units.
With this option selected, take extra care with the configuration of the operating units.
Option of blocking the master
(disable opening the lock and registering new users)
Locally (via user matrix in PC software), you can configure the master in such a way that
sh
e / he cannot open (user matrix: box “open”) / cannot open and cannot register new
users (
user matrix: box “release”).