background image

ENGLISH

 

 

 

Quick Installation Guide 

MoRoS LAN 

 

 

www.insys-icom.com 

These short operating instructions apply for the following devices of INSYS icom: 

 

MoRoS LAN 2.x PRO

 

 

www.insys-icom.com/manual 

 

 

It is intended for a quick commissioning by the operator. Refer to the associated manual for further information. 
This and other associated manuals can be found on our website in the menu Support and Downloads > 
Documentation. Scan the QR code above or enter the URL into your web browser.

 

 

Defects liability terms 
A use other than the intended use, an ignorance of the safety instructions and the documentation, the use of insufficiently qualified 
personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resulting from this. The liability of the 
manufacturer ceases to exist. 

Intended Use 
The product may only be used for the purposes specified in the function overview of the manual. In addition, it may be used for the 
following purposes: 

 

Usage and mounting in an industrial cabinet. 

 

Switching and data transmission functions in machines according to the machine directive 2006/42/EC. 

 

Usage as data transmission device, e.g. for a PLC. 

The product may not be used for the following purposes and used or operated under the following conditions: 

 

Use, control, switching and data transmission in machines or systems in explosive atmospheres. 

 

Controlling, switching and data transmission of machines, which may involve risks to life and limb due to their functions or when a 
breakdown occurs. 

Technical Boundaries 
Max. line length for power supplies, inputs and outputs as well as other signals: 30 m 
Max. line length of serial connection lines: 3 m 
Cable cross-

section: 0.25 … 2.5 mm², flexible lines require end sleeves

 

Support 
If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e-mail 
under [email protected]

Technical Data 
The product is only intended for the use within the permissible technical limits specified in the data sheets. These limits must be observed. 
 

Operating voltage 

10 

V … 60

 V DC (±0%) 

Real-time clock (RTC) buffer time 

typ. 2 days 

Power consumption 

typ. 2.0 W, max. 3.0 W 

Temperature range 

-30 

°C … 70

 °C 

(85 °C restricted) 

Level inputs 

HIGH level = 3 ... 12 V 
LOW level = 0 ... 1 V  
Contact open condition: HIGH 

Maximum permissible humidity 

95% non-condensing 

Current consumption input at 
LOW potential 

max. 0.5 mA when connecting 
to GND 

IP rating 

Housing IP40  
Connectors IP20  

Digital output (changeover 
relay), max. switch voltage 

30 V (DC) / 42 V (AC) 

 

 

Digital output (changeover 
relay), max. current load 

1 A (DC) / 0.5 A (AC) 
(resistive load) 

 

 

 

Содержание MoRoS LAN

Страница 1: ...llowing purposes and used or operated under the following conditions Use control switching and data transmission in machines or systems in explosive atmospheres Controlling switching and data transmission of machines which may involve risks to life and limb due to their functions or when a breakdown occurs Technical Boundaries Max line length for power supplies inputs and outputs as well as other ...

Страница 2: ...mmended to unplug the network cable briefly and plug it again upon activation of the DHCP client Configure a static IP address Use the following IP address example IP address 192 168 1 2 Subnet mask 255 255 255 0 Standard gateway 192 168 1 1 Preferred DNS server 192 168 1 1 Please note the previous values before changing the TCP IP settings to be able to restore them later C Web interface access 8...

Страница 3: ...ttps connectivity insys icom de 11 Confirm settings with OK The COM LED is illuminated green during PPPoE connection establishment and orange as soon as a connection is established If a connection to the icom Connectivity Suite VPN is configured the Status LED will light up green as soon as it is established E Configuration of access data User name and password for web interface access must be cha...

Страница 4: ...ft reset Resetting the router to default settings If the router is to be reset to default settings if the router has already been used for example it can be reset to delivery state 1 Menu System Reset Select Load default configuration and reset 2 Confirm settings with OK Alternatively press reset key on the device front three times for a short time within 2 seconds Resetting and initialising the r...

Отзывы: