i-modul Modem 336 LL
Functions
6
Functions
6.1
Automatic Baud Rate Detection
6.1.1
Serial Connection
The automatic baud rate detection enables a continuous automatic adjustment of all
parameters (baud rate, data format) of the serial interface at the i-modul Modem 336 LL
3.0 in configuration mode. The device will detect during the operation in configuration
mode, which baud rate and which data format is applied to the serial interface. If this
setting is stored, the i-modul Modem 336 LL 3.0 will restore the stored interface configu-
ration after a restart. With each incoming AT command (according to the character
string "AT"), the parameters for the interface of the i-modul Modem 336 LL 3.0 will be
checked and adjusted, if necessary.
The function is active as default.
Configuration with AT commands
In order to change the i-modul Modem 336 LL 3.0 to configuration mode,
press the reset key for one second. The i-modul Modem 336 LL 3.0 reacts on
AT commands in this mode. Otherwise, AT commands entered via the termi-
nal program are considered as incoming data and forwarded to the remote
terminal. If no entry is made for more than 120 seconds in configuration
mode, the i-modul Modem 336 LL 3.0 returns to online mode.
To set a baud rate at the serial interface of the
i-modul Modem 336 LL 3.0, enter an AT com-
mand in
configuration mode
or simply
AT
Store the baud rate using the command
AT&W
15