Technical Data
INSYS GSM 4.3
6
Technical Data
6.1
Physical Features
All specified data was measured with a nominal input voltage, at full load, and an
ambient temperature of 25 °C. The threshold value tolerances are subject to typical
fluctuations.
Physical Feature
Value
Operating voltage
minimum 10 V DC
maximum 60 V DC
Power input sleep
2 W
Power input connection
2.5 W
Maximum power input (during 577
µs
lasting GSM transmit burst)
10 W
Level alarm inputs
Level HIGH = 4-12 V
Level LOW = 0-1 V
Input current from GND to in5 V typically 0.5 mA
Switch output, maximum switch voltage 30 V (DC) / 42 V (AC)
Switch output, maximum current load
1 A (DC) / 0.5 A (AC)
Minimum operating voltage SIM cars
3 V
Emitted radiation:
EGSM 900: Class 4
GSM 1800: Class 1
EGSM 900: Class E2
GSM 1800: Class E2
2 W
1 W
0.5 W
0.5 W
Weight
270 g (INSYS GSM 4.3)
218 g (INSYS GSM 4.3 compact)
Dimensions (Width x Depth x Height)
55 x 110 x 75 mm (INSYS GSM 4.3)
82 x 58 x 84 mm (INSYS GSM 4.3
compact)
Temperature range
0 °C – 55 °C (INSYS GSM 4.3)
-20 °C – 55 °C (INSYS GSM 4.3 com-
pact)
Maximum allowed humidity
95% non-condensing
Protection Class
Housing IP40, Terminals IP20
Table 1: Physical Features
20