Quick Installation Guide 

EBW-W 

 

 

www.insys-icom.com 

These short operating instructions  apply for the following  devices of INSYS icom:  

 

EBW-W100

 

 

www.insys-icom.com/manual 

 

 

It is intended for a quick commissioning  by the operator. Refer to the  associated  manual for further information. 
This and other associated  manuals can be found on our website  in the menu Support > Documentation   and 
Downloads. Scan the QR code above or enter the URL into your web browser.

 

 

Defects liability terms 
A use other than the intended use, an ignorance of the safety instructions and the documentation, the use of insufficiently qualifi ed 
personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resulting from this. Th e liability of the 
manufacturer ceases to exist. 
In tended Use 
The product may only be used for the purposes specified in the function overview of the manual. In addition, it may be used f or the 
following purposes: 

 

Usage and mounting in an industrial cabinet. 

 

Switching and data transmission functions in machines according to the machine directive 2006/42/EC. 

 

Usage as data transmission device, e.g. for a PLC. 

The product may n ot be used for the following purposes and used or operated under the following conditions: 

 

Use, control, switching and data transmission in machines or systems in explosive atmospheres. 

 

Controlling, switching and data transmission of machines, which may involve risks to life and limb due to their functions or when a 
breakdown occurs. 

Technical Boundaries 
Max. line length for antennas, power supplies, inputs and outputs as well as other signals: 30 m 
Cable cross-

section: 0.25 … 2.5 mm², flexible lines require end sleeves

 

Support 
If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e-mail 
under [email protected]

Technical Data 
The product is only intended for the use within the permissible technical limits specified in the data sheets. These limits m ust be observed. 
 

Operating voltage 

10 

V … 48

 V DC (±20%) 

Real-time clock (RTC) buffer time 

typ. 2 days 

Power consumption 

typ. 2.0 W, max. 3.0 W 

Temperature range 

-30 

°C … 70

 °C 

(85 °C restricted) 

WLAN 

2.4 GHz; 802.11b/g/n 

Maximum permissible humidity 

95% non-condensing 

 

 

IP rating 

Housing IP40  
Connectors IP20  

 