INSTEON Setup 

Some products have subtle differences in their setup procedures. Please refer to the other devices’ owner’s 
manuals for details.  

INSTEON Controllers, Responders and Links 

Let’s define a few terms. 

  The INSTEON “transmitter” is called a 

controller

 

  The INSTEON “receiver” is called a 

responder

 

  The association between the controller and responder is called a 

link

 

 

Note that a link is one way. If you wish to have control “the other way,” simply add a link “the other way.” 

 

Make On/Off Outdoor Module a Responder 

1)  Press and hold controller set button until it beeps 

Controller LED will start blinking 
You will have four minutes to complete the next steps before linking mode times out

 

2)  Use On/Off Module set button to adjust load to desired state (on or off) 
3)  Press and hold On/Off Outdoor Module set button until it double-beeps 

Controller will double-beep and its LED will stop blinking

 

4)  Test link by tapping controller button on and off  

Lamp connected to On/Off Outdoor Module will respond appropriately 

Note: 

The link just created is one way. Se

Make On/Off Outdoor Module a Controller

 

or 

Groups

 

to add another 

link to keep the two products in sync. 

If you wish the load to be off when link is activated—such as for an “all off” scene—turn off the load in step 
#2. 

 

Make On/Off Outdoor Module a Controller 

1)  Press and hold On/Off Module set button until it beeps 

On/Off Module LED will start blinking green

 

2)  Adjust responder to desired brightness state (such as on, 50% or even off) 

3)  Press and hold responder set button until it double-beeps 

On/Off Module LED will stop blinking 

4)  Test by tapping On/Off Module set button to turn on/off 

Responder will respond appropriately

Controller 

Responder 

Link 

Содержание 2634-222

Страница 1: ...Page 1 of 13 2634 222 Rev 2 11 2019 9 16 AM On Off Outdoor Module Owner s Manual 2634 222...

Страница 2: ...rollers Responders and Links 6 Make On Off Outdoor Module a Responder 6 Make On Off Outdoor Module a Controller 6 Groups 7 Scenes 7 Remove On Off Outdoor Module as a Responder 7 Remove On Off Outdoor...

Страница 3: ...s and links to other INSTEON devices in minutes Controls standard incandescent loads up to 1440 Watts and inductive loads up to 12 Amps Weatherproof to withstand harsh outdoor conditions Indicates INS...

Страница 4: ...GFCI device Don t bury On Off Outdoor Module any electrical cable or component connected to it A buried power cord may result in electrocution if improper cables are used or if digging occurs over the...

Страница 5: ...ntroller On Off Outdoor Module LED will blink green for INSTEON traffic and if it detects noise that could disrupt communication Programming Lock Default disabled This setting is only adjustable via s...

Страница 6: ...ad to desired state on or off 3 Press and hold On Off Outdoor Module set button until it double beeps Controller will double beep and its LED will stop blinking 4 Test link by tapping controller butto...

Страница 7: ...as a member 1 Press and hold controller set button until it beeps Controller LED will start blinking green 2 Tap controller set button Controller LED will start double blinking green 3 Use On Off Modu...

Страница 8: ...ing is disabled on On Off Outdoor Module by default but you can enable it by following these steps Enable Load Sensing 1 Press and hold On Off Outdoor Module set button until it beeps 3 seconds On Off...

Страница 9: ...400 LED Green when load is on red when load is off Blinks red or green during setup Beep on button press No Local control Yes Commands supported as controller On Off Commands supported as responder On...

Страница 10: ...ng temperature range 4 to 122 F 20 to 50 C Storage temperature range 4 o to 158 o F 20 o to 70 o C Operating humidity range 0 90 relative humidity Electrical Voltage 120 Volts AC 10 Frequency 60Hz Loa...

Страница 11: ...to a controller The controller may be sending commands to a responder that is no longer in use Commands for the unused responder are being resent and loading down the signal Unlink any unused responde...

Страница 12: ...evice does not provide a phase bridge to Micro module Relocate if necessary and practical If the other dual band device is not blinking Device is not within RF range of Micro module so it does not pro...

Страница 13: ...lament de tungstene afin de reduire le risqu de surchauffe et la possibilite d endommagement a d autres materiels ne pas installer pour commander une prise un appareil a moteur une lampe fluorescente...

Отзывы: