UNDER-COUNTER,

PUSH BUTTON DISPENSER

INSTALLATION &

USER INSTRUCTION MANUAL

IB24

Содержание UCD12

Страница 1: ...UCD SERIES UNDER COUNTER PUSH BUTTON DISPENSER INSTALLATION USER INSTRUCTION MANUAL IB24 ...

Страница 2: ...es near boiling water During normal use of the boiler all surfaces remain cool However care should be taken to avoid potential injury from burns and scalding whilst dispensing water from the font Scale formation within the hot water appliances can be problematic in hard water areas Damage to the appliance caused by excessive scale build up may invalidate the warranty See notes on de scaling ENVIRO...

Страница 3: ...Time from Cold 33 Minutes to full boiler capacity Model Ref No UCD47 UCD47 D 4 5kw standard configuration Description Under counter push button dispense Boiler Voltage 220 240v Single phase 50Hz Supply AC Rated Input 4 5kW standard configuration Output Amps 20A Fill Type Automatic Max Rapid Draw Off 47 Litres 235 x 200ml 7oz cups Recovery per Minute 0 75 Litres Temperature Adjustable between 80 95...

Страница 4: ... away from underside of counter top A set of two ventilation grill pannels made from brushed stainless steel c w fixing screws is available from Instanta spares dept Part No UCVENT1 MAINS WATER CONNECTION Your machine has been supplied with a WRAS approved non toxic hose for connection to a suitable drinking water supply The water supply must have a pressure not exceeding 7bar 96psi and no lower t...

Страница 5: ...provide protection from flooding ELECTRICAL CONNECTION UCD7 and UCD12 3 0kw MODELS Your machine is supplied with a standard 3 pin bonded plug and lead with 13amp fuse UCD47 4 5kw Standard Configuration suitable for 20amp supply Your machine is supplied with a 2mtr long electrical cord 3 x 2 5mm for connection to a suitable 20A single phase electrical supply via an isolation switch Optional Configu...

Страница 6: ...47 2 boiler is supplied with two independant water fonts each of which can be set to deliver a different measured volume Set the first water font VEND H F1 as already described above then scroll through the menu to the next selection VEND C F2 Repeat the instructions as above to set measured volume of second water font PROGRAM ON DEMAND WATER DISPENSE If preferred the water font can be configured ...

Страница 7: ...with an intelligent fault diagnosis system There are two levels of diagnosis 1 Simple Warnings accompanied by the illumination of a red exclamation mark Your boiler will continue to operate as normal whilst displaying these warnings 2 Critical Faults accompanied by the illumination of a red spanner Simple Warnings 1 The following messages may be seen The display will alternate between the boiler s...

Страница 8: ...resolve the fault the boiler has overfilled This may have been caused by a faulty water inlet valve or very high or low incoming water pressure Consult with your supplier or phone Instanta service department on 01704 502911 or if this number is engaged 01704 501114 10 0 CLEANING The external surfaces of the water font can be kept clean by wiping with a damp cloth Do not use abrasive material on th...