BMC Settings
73
9 BMC Settings
9.1 Introduction
This Specification describes the functional specifications for the Baseboard Management
Controller (BMC). It also describes the feature’s detail information.
This document is written for software developers, system integrators, testers, server
management users.
9.2 Server System Overview
BMC is an independent system of host server system. This independent system has its
own processor and memory; the host system can be managed by BMC system even if host
hardware or OS hang or went down.
9.2.1 Main Feature
●
Support IPMI 2.0, IPMI Interface includes KCS, Lan, IPMB
●
Management Protocol, IPMI2.0, HTTPS, SNMP, Smash CLI
●
Web GUI
●
Redfish
●
Management Network Interface, Dedicated/NCSI
●
Console Redirection (KVM) and Virtual Media
●
Serial Over Lan (SOL)
●
Diagnostic Logs, System Event Log (SEL), Blackbox Log, Audit Log
●
Hardware watchdog timer; Fans will full speed when BMC no response in 4 mins
●
Intel® Intelligent Power Node Manager 4.0 support
●
Event Alert, SNMP Trap (v1/v2c/v3), Email Alert and Syslog
●
Dual BMC firmware image support
●
Storage, Monitor RAID Controller/HDD/Virtual HDD
●
Firmware update, BMC/BIOS/CPLD
●
Device State Monitor and Diagnostic
●
RAID Monitor/Configure
9.2.2 Integrated BMC Hardware
ASPEED AST2500 is the processor of server management subsystem, based on
Содержание NF8480M5
Страница 1: ...Inspur Server User Manual NF8480M5 ...
Страница 51: ...45 BIOS Setup b It will display the memory RAS configuration by entering the Memory RAS Configuration submenu ...
Страница 66: ...60 information 3 2 Create RAID Volume Enter this menu interface as shown below ...
Страница 92: ...86 sensor Figure 6 Sensor fru Figure 7 Fru chassis Figure 8 Chassis user Figure 9 User ...
Страница 93: ...BMC Settings 87 mc Figure 10 MC fan Figure 11 Fan psu Figure 12 Psu id Figure 13 Id diagnose ...