128
9.21.3 Power Peak
Power peak is used to prevent many servers from being started at the same time when first
time A/C power is restored, which would cause heavy power loading.
●
Power peak can be enabled or disabled. Disabled by default.
●
When it is enabled, users can configure the maximum random time.
●
BMC will power on server with a random time delay within the time configured.
Click “Power and Fan -> Power Peak” to go to the configuration page.
Figure 45 Power Peak
9.21.4 Power Limit
BMC provides power cap function, power cap function sets the power limit for the system,
and when the system power exceeds this upper limit, Intel ME will slow down the CPU to
reduce power consumption. Power cap will affect the server performance, professional
maintenance personnel will operate when needed.
Go to page “Power and Fan->Power Consumption” to check and configure.
Figure 46 Power Limits
9.21.5 Power Consumption Statistics and History Record
BMC provides curve-based inlet temperature and power monitoring statistics.
Administrators can gain insight into the actual use of electricity and cooling resources
through energy monitoring devices. Users can optimize the server’s energy savings based on
historical data.
Go to page “Power Management-> Power statistics”, and this page displays the system
Содержание NF8480M5
Страница 1: ...Inspur Server User Manual NF8480M5 ...
Страница 51: ...45 BIOS Setup b It will display the memory RAS configuration by entering the Memory RAS Configuration submenu ...
Страница 66: ...60 information 3 2 Create RAID Volume Enter this menu interface as shown below ...
Страница 92: ...86 sensor Figure 6 Sensor fru Figure 7 Fru chassis Figure 8 Chassis user Figure 9 User ...
Страница 93: ...BMC Settings 87 mc Figure 10 MC fan Figure 11 Fan psu Figure 12 Psu id Figure 13 Id diagnose ...
Страница 143: ...BMC Settings 137 Figure 56 SOL Setting in BIOS Figure 57 Default Serial Setting ...