126
The “Remote Control -> Locate Server” page shows the status of UID.
Turn on UID: Specify the light time period, and click “Turn On Led” button to turn on UID for
specified time.
Turn off UID: Click “Turn Off Led” button to turn off UID.
Figure 42 Server Location
9.20.2 Server Virtual Power Button
This function allows users to power on, off, and reset the managed server via BMC.
●
Power on, same to short time pressing power button.
●
Forcedly power off, same to long time pressing power button.
●
Power cycle, power off, delay 10s, power on.
●
Hard reset, same to short time pressing reset button (if present).
●
Soft shutdown, orderly power off, same to short time pressing power button.
Supported:
Web GUI
IPMI command based on IPMI2.0.
Page “Remote Control -> Server Power Control” shows current power status. Users can
perform power control actions.
Figure 43 Virtual Power Button
Содержание NF8480M5
Страница 1: ...Inspur Server User Manual NF8480M5 ...
Страница 51: ...45 BIOS Setup b It will display the memory RAS configuration by entering the Memory RAS Configuration submenu ...
Страница 66: ...60 information 3 2 Create RAID Volume Enter this menu interface as shown below ...
Страница 92: ...86 sensor Figure 6 Sensor fru Figure 7 Fru chassis Figure 8 Chassis user Figure 9 User ...
Страница 93: ...BMC Settings 87 mc Figure 10 MC fan Figure 11 Fan psu Figure 12 Psu id Figure 13 Id diagnose ...
Страница 143: ...BMC Settings 137 Figure 56 SOL Setting in BIOS Figure 57 Default Serial Setting ...