Server Entrance and Runtime
Environment Requirements
Ambient Temperature
Table 11-1 Ambient Temperature
Item
Status
Specifications
Temperature
Continuous operation
10°C to 35°C (50
o
F to
95
o
F
)
Transportation (Storage) –40°C to +70°C (–40
o
F to
+158
o
F
)
Maximum temperature
gradient (operation and
storage)
20°C/h (68
o
F
/h)
Humidity
Operation
Relative humidity: 5% to 90%.
Maximum dew-point temperature: 32°C
(89.6
o
F)
Transportation (Storage)
Maximum dew-point temperature: 39°C
(102.2
o
F).
Relative humidity: 5% to 95%, non-
condensing
Reliability
Table 11-2 Reliability
Item
Status
Specifications
Vibration
Operating
0.21 Grms at 5 to 500 Hz (15 min per axis,
including X, Y, and Z axes)
Transportation
(Storage)
2.2 Grms at 5 to 500 Hz (10 min per axis,
including X, Y, and Z axes)
Shock
Operating
In the positive and negative directions of the
x, y, and z axes, each axis can withstand 100
continuous 2 G shock pulses with a maximum
duration of 11 ms.
Transportation
(Storage)
In the directions x, y, and z axes, each axis
can withstand 1,000 continuous 40 G
shock pulses with a maximum duration of
6 ms.
Содержание NF5260FM6
Страница 1: ...Inspur Server NF5260FM6 User Manual Document Version V1 0 Release Date 2021 05 28 ...
Страница 27: ...19 Item 2 Top PCIe0 1 2 Slot Bottom OCP 3 0 NIC 3 Drive Bay 9 4 PSU ...
Страница 32: ...24 Figure 4 4 Removing the air director ...
Страница 44: ...36 Figure 5 16 Installing the fan module 4 Repeat steps 2 3 to install the remaining fan modules ...