55
Figure 4-51 Installing the CPU
4.
Remove the protective cover if present.
5.
With the gold pins down, align the triangle mark on the CPU with that on the
heatsink to attach the PHM onto the CPU socket.
6.
Press the four lock-in wires outward with both hands simultaneously.
7.
Tighten the four screws securing the PHM to the CPU socket clockwise in the
sequence as shown on the heatsink label with a T30 Torx screwdriver.
8.
Install the crossbar.
9.
Install the air duct.
10.
Install the access panel.
4.4.13
PCIe Card Replacement
To prevent damage to the server or expansion cards, power down the server
and remove all power cables before removing or installing the PCIe card.
To prevent damage to the PCIe slot pins, be sure to apply even force and
pull and insert the PCIe card vertically.