30
Figure 4-7 Removing the Super-Capacitor
To install the super-capacitor:
1.
Take the new super-capacitor out from the antistatic bag and position it in the
battery holder.
2.
Secure the super-capacitor with velcro.
3.
Connect the cable of the super-capacitor.
4.
Install the crossbar.
5.
Install the air duct.
6.
Install the access panel.
4.4.5
Hot-Swap Fan Module Replacement
Be sure to wear work gloves during operation to avoid scratches by sharp parts
on the equipment.
To remove the fan module:
1.
Remove the access panel (Refer to Access Panel Replacement).
2.
Locate the fan module to be replaced. The server supports up to 8 fan modules.