Pre-Disassembly Instructions
Read the installation instructions for all the hardware operations before disassembling
or re-assembling the components. All prerequisites must be completed prior to starting
installation or maintenance.
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching.
To prevent damage to electrical components, properly ground the server before
installation. Improper grounding can cause electrostatic discharge.
Do the following prior to installation or maintenance:
1.
Back up all the data on the server.
2.
Shut down the server.
3.
Remove all cables from the system.
4.
Remove the system from the rack.
To reduce the risk of personal injury or equipment damage, be sure that the
rack is adequately stabilized before you extend a component from the rack.
To reduce the risk of personal injury, be careful when sliding the server into
the rack. The sliding rails could pinch your fingers.
To remove the server from the rack:
1.
Open both handles on the front panel of the server, and then loosen the two
captive screws securing the server in place.
2.
Gently slide and remove the server out of the rack.