insize ISR-S300 Скачать руководство пользователя страница 1

MN ISR

300

-

-S

-E

www

.

insize

.

com

ROUGHNESS TESTER 

OPERATION

 

MANUAL

ISR-S300

V0

Содержание ISR-S300

Страница 1: ...MN ISR 300 S E www insize com ROUGHNESS TESTER OPERATION MANUAL ISR S300 V0 ...

Страница 2: ... a microprocessor it uses an alphanumeric liquid crystal display LCD and the accumulator adopted permits considerable operating autonomy All the messages and menus can be displayed in one of the following five selectable languages Italian English French German Spanish and Portuguese The instrument consists of the electronic unit the miniaturised traverse unit incorporated and where applicable a pr...

Страница 3: ...n of the items on the top part is as follows 1 2 On off START start measurement STOP stop measurement key 3 Key for displaying the result of the measurement displaying and presetting the cut off and cut off number If pressed when in Liquid crystal display LCD the main menu causes the higher level menu to return on display 4 Scroll key If pressed when the result of a measurement is on display bring...

Страница 4: ... shows 1 The results of a measurement 2 The cut off 3 The cut off number 4 An error message To exit from the main menu and the submenus press the and the first one immediately starts the measure the second in the submenus makes to climb a level in the main menu it makes to visualize the parameters The structure of the menu can be seen in the figure that follows The selections made on the submenus ...

Страница 5: ...ayed because the assessment of the parameters is strictly related to λc and to the number of λc used When the cut off or cut off number is changed on an instrument already preset for measurement setting of the cut off may be terminated with the key which immediately starts the measuring cycle 4 How to preset the traverse length with ISO 12085 When the ISO 12085 standard is used the measurement ran...

Страница 6: ...selection on the item Position and press The following indication will be obtained where the vertical arrow indicates current position of the stylus while the horizontal line below it represents the total excursion of the stylus during the positioning session In order to obtain correct measurements the arrow must be in the centre of the field defined on the display coinciding with the zero point o...

Страница 7: ...rated in the examples that follow 11 12 Note if you need to check the value of a disabled parameter and you have just finished measuring simply enable the parameter concerned It is not necessary to complete the measurement The parameter Rmr represents the bearing ratio and it is also graphically printed as curve of Abbott 8 Setting the calculating standard 1 In the main menu make your selection on...

Страница 8: ...menu Files Eliminating all the measurements stored 1 In the main menu make your selection on the item Files and press to bring up the submenu 2 Make your selection on the item Reset and press Press to go back to the main menu 16 Operations When performing measurements to get a correct result there are a number of hints that should be observed 1 Where possible place the instrument and the part bein...

Страница 9: ... is left connected for more than this time because it is provided with an automatic charge control means It is possible to use the instrument even while the accumulator battery is recharging Note do not store the instrument for long periods with the accumulator battery discharged as it will become damaged If left idle for long periods check the charge level at least once every 30 days If the accum...

Страница 10: ... receiver is not programmed correctly c The connection cable is damaged Signalled when the diagnostic checks reveal a memory defect Remedies call the technical service department Signalled at the end of a measurement when with the ISO 12085 standard selected the instrument s calculating capacity is exceeded Probable cause The profile examined cannot be gauged Resetting The Storage Memory If there ...

Отзывы: