Product Description 

LPS1800  Outdoor  Industrial  PoE  Switch  features  with  four  PoE  Ethernet  ports  and  comply  to 
10/100Mbps, IEEE802.3at/af PoE and two Gigabit SFP fiber optics interfaces. The power supply of single 
PoE port can be  up to 15.4W for 802.3af and 25.5W for 802.3at.   The transfer data can be up to 120Km 
from  SFP  fiber  port  to  a  control  center.    Additionally,  the  product  also  features  with  an  anti-
electromagnetic interference that is designed for harsh outdoor applications and the 3KV network port 
surge protection can adapt to harsh outdoor environment and ensure the reliability of the uninterrupted 
PoE operations.  The outdoor enclosure is rated at IP68, and the system is able to operate under -

40 ~ +75 ˚ 

C temperature range.

 

Product Features 

1.

 

Comply  to  IEEE  802.3,  IEEE   802.3u,  IEEE  802.3z,  IEEE  802.3ab,  IEEE  802.3x,  IEEE  802.1D,  IEEE 
802.3at,  IEEE  802.3af,  IEEE  802.1Q  IEEE  802.1p,  IEEE  802.1x,  IEEE  802.1W,  SNMP,  IGMP 
standards

 

2.

 

10/ 100M  self-sensing  RJ45  port, support  PoE power  supply function; All ports  support  auto-flip 
(Auto MDI/MDIX);

 

3.

 

Each  PoE  port  can  provide  power  up  to  15.4W  p er  IEEE 802.3af  standard;  Supply  power  for 
powered  devices compatible  with IEEE802.3af;

 

4.

 

Each  PoE  port  can  provide  power  up  to  25.5W  p er  IEEE 802.3at  standard;  Supply  power  for 
powered  devices compatible  with IEEE802.3at;

 

5.

 

Support  IEEE802.3x  full duplex flow control and duplex backpressure flow control;

 

6.

 

8.8G backplane  bandwidth;

 

7.

 

1K MAC address  table;

 

8.

 

Its  3KV  network  port  surge  protection    can  adapt  to  harsh  outdoor  environment;  Under  the 
temperature  of -40 ~ +75 

˚

 C, working  at a full load 150W for 802.3af and 225W for 802.3at;

 

9.

 

The  2 gigabit  SFP  fiber  ports  are  capable  of  high  bandwidth and  for  up  to  120KM  long  distance 
transmission.

 

Installation 

a.

 

Before installation, please ensure the following: 

b.

 

All PD devices, i.e., PoE Clients, meet the power requirement of the connecting devices. 

c.

 

All PD devices, i.e., PoE Clients, match with the power receiving device power pinout 
specification (1/2+ & 3/6-) 

d.

 

Connect the power cable to a power source, 110 ~ 240V AC, then the switch will automatically 
initialize, and LED lights status will display as following: 

e.

 

Except the POE port lights, all the other lights will go through the process of “on

-off-on-

off”, 

which means the installation is successful. 

f.

 

Sys (Power) LED remains ON 

g.

 

Connect the network devices with network cables to the POE switch port though the waterproof 
connectors, then secure  the Top Cover with the four screws to the Bottom Case 

h.

 

After the Ethernet and/or fiber optics network devices are connected, please refer the LED 
Indicator Description Table Below on Page 6 

Содержание Link Power LPS1800-T1

Страница 1: ...ght 2015 Inscape Data Corporation All Rights Reserved LinkPower AirEther AirGoogle and Inscape Data are trademarks of Inscape Data Corporation Disclaimer While every effort is made to ensure the infor...

Страница 2: ...at changes and modifications made to the equipment without approval of the manufacturer could void the user s authority to operate this equipment The manufacturer is not responsible for any radio or T...

Страница 3: ...chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power cable with the third wire firmly connected t...

Страница 4: ...equipment must comply with local and national electrical codes Do Not Exceed Input and Output Ratings Do not operate the product to exceed the power input and output ratings This product Conforms to t...

Страница 5: ...et Fiber Optics Power Connector Assembly Diagram 8 IP Management Login Managed Models Only 8 Grounding Protection 8 Grounding the Switch by Using the AC Power Cord 8 Power Redundancy UPS Input 9 RESET...

Страница 6: ...power up to 25 5W per IEEE802 3at standard Supply power for powered devices compatible with IEEE802 3at 5 Support IEEE802 3x full duplex flow control and duplex backpressure flow control 6 8 8G backp...

Страница 7: ...10 100M Indicator Link OFF No Connected PD or Power OFF Yellow LED Blink Data transmission properly Yellow LED ON Connected with 10Mbps or 100Mbps network device OFF No connected PD L A Indicator Link...

Страница 8: ...tion of the system It is highly recommended that you re to perform both grounding procedures for maximum safety and protection of your equipment However at least of the grounding MUST be performed oth...

Страница 9: ...WIRE of the AC DC Power Cords Is Used for Grounding Power Redundancy UPS Input The switch offers dual power redundancy i e AC DC input There are two power inputs as shown below diagram When the AC in...

Страница 10: ...3 13A DC power Please note the DC Power Cord Kit Part WPCK 004 is an optional accessory RESET Switch System Reset Managed Models Only There are two ways to reset the system i e software reset and hard...

Страница 11: ...Page 11 Installation Mounting You can mount the system with one of the two ways 1 Wall Mount Wall Mount Kit Standard Accessory 2 Pole Mount Optional Accessory MMK001 Pole Mount Kit...

Страница 12: ...Page 12 Product Dimensions Wall Mount Pole Mount...

Страница 13: ...Page 13 Appendix I Technical Specifications ELECTRICAL PIN OUT DIAGRAM...

Страница 14: ...nscapedata com U S Headquarters Here s how to reach us if you d like to place an order or if you have questions concerns or need support Telephone Postal Mail North and South America Customer Service...

Отзывы: