Inscape Data Link Power LPS1800-T1 Скачать руководство пользователя страница 1

Page | 1 
 

 

 

Link Power

 LPS1800-T1 

Outdoor Industrial 8-Port PoE, 2-Port 

Combo RJ45/SFP Network Switch 

 

USER MANUAL 

 

 

Inscape Data Corporation 
1620 Oakland Road, STE D101 
San Jose, CA 95131 
U.S.A. 

 
 
© Copyright 2015, Inscape Data Corporation, All Rights Reserved. LinkPower,  AirEther,  AirGoogle, 
and Inscape Data are trademarks of Inscape Data Corporation 

Disclaimer: While every effort is made to ensure the information given is accurate, Inscape Data 
Corporation does not accept liability for any errors or mistakes which may arise. All information and 
specifications are subject to change without notice. 

Содержание Link Power LPS1800-T1

Страница 1: ...ght 2015 Inscape Data Corporation All Rights Reserved LinkPower AirEther AirGoogle and Inscape Data are trademarks of Inscape Data Corporation Disclaimer While every effort is made to ensure the infor...

Страница 2: ...at changes and modifications made to the equipment without approval of the manufacturer could void the user s authority to operate this equipment The manufacturer is not responsible for any radio or T...

Страница 3: ...chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power cable with the third wire firmly connected t...

Страница 4: ...equipment must comply with local and national electrical codes Do Not Exceed Input and Output Ratings Do not operate the product to exceed the power input and output ratings This product Conforms to t...

Страница 5: ...et Fiber Optics Power Connector Assembly Diagram 8 IP Management Login Managed Models Only 8 Grounding Protection 8 Grounding the Switch by Using the AC Power Cord 8 Power Redundancy UPS Input 9 RESET...

Страница 6: ...power up to 25 5W per IEEE802 3at standard Supply power for powered devices compatible with IEEE802 3at 5 Support IEEE802 3x full duplex flow control and duplex backpressure flow control 6 8 8G backp...

Страница 7: ...10 100M Indicator Link OFF No Connected PD or Power OFF Yellow LED Blink Data transmission properly Yellow LED ON Connected with 10Mbps or 100Mbps network device OFF No connected PD L A Indicator Link...

Страница 8: ...tion of the system It is highly recommended that you re to perform both grounding procedures for maximum safety and protection of your equipment However at least of the grounding MUST be performed oth...

Страница 9: ...WIRE of the AC DC Power Cords Is Used for Grounding Power Redundancy UPS Input The switch offers dual power redundancy i e AC DC input There are two power inputs as shown below diagram When the AC in...

Страница 10: ...3 13A DC power Please note the DC Power Cord Kit Part WPCK 004 is an optional accessory RESET Switch System Reset Managed Models Only There are two ways to reset the system i e software reset and hard...

Страница 11: ...Page 11 Installation Mounting You can mount the system with one of the two ways 1 Wall Mount Wall Mount Kit Standard Accessory 2 Pole Mount Optional Accessory MMK001 Pole Mount Kit...

Страница 12: ...Page 12 Product Dimensions Wall Mount Pole Mount...

Страница 13: ...Page 13 Appendix I Technical Specifications ELECTRICAL PIN OUT DIAGRAM...

Страница 14: ...nscapedata com U S Headquarters Here s how to reach us if you d like to place an order or if you have questions concerns or need support Telephone Postal Mail North and South America Customer Service...