10
6.Maintenance
(B) 2020/11
Do not spray the hot parts of the pump with water, since some parts might crack
and pump fluid could spill into the environment, thereby creating a potentially
explosive atmosphere.
An external cleaning of the equipment should be carried out to prevent excessive
accumulation of combustible or explosive powder on the outside surface of the
equipment. Under no circumstances should it be allowed to accumulate to a
thickness in excess of 2 mm
6.3.
ASSEMBLY / DISASSEMBLY OF THE PUMP
Improper assembly or disassembly of the equipment can impair operation of the
pump, cause high repair costs, long downtime and even render the protective
system of the equipment ineffectual.
INOXPA disclaims any responsibility for accidents or damage caused by failure to observe the instructions
of the manual and of this Annex.
In addition to the instructions included in the manual, the instructions of the motor's manufacturer must
also be followed strictly in order to open the motor safely.
6.3.1.
Pump and single mechanical seal
¡ATTENTION! Fluid might spill when removing the pump casing and a potentially
explosive atmosphere might develop.