The attached table lists solutions to problems that may arise while operating the agitator. It is assumed that the
agitator has been properly installed and that is has been selected correctly for the specific application.
Contact INOXPA if technical assistance is required.
Motor overload
Insufficient agitation
Vibrations and noise
Leaks
PROBABLE CAUSES
SOLUTIONS
Viscosity of the liquid too high
Reduce the viscosity, e.g. by heating
the liquid
High density
Increase motor power
Tank too big for the chosen agitator
Check with the technical department
Wrong direction of rotation
Change direction of rotation
Agitator speed too low
Increase the speed
Liquid level insufficient or none
Check liquid level in the tank
Shaft vended
Replace the shaft
Critical speed
Check with the technical department
Worn bearings
Replace the bearings agitator
Lip seal damaged or worn
If the lip seal is worn, replace it.
If the lip seal is damaged, consult the
technical department.
V-ring worn or damaged
Replace the V-ring
If the problems persist stop using the agitator immediately. Contact the agitator manufacturer or the
representative.