Inovonics EN2222S-60 Скачать руководство пользователя страница 1

3.30.22 357-00057-02 Rev A © Inovonics, 2022 - www.inovonics.com

EN2222S-60 Fall Detect Pendant

Installation and Operation Manual

1 Overview

The EN2222S-60N fall detect pendant sends an automatic alarm message 

when sensors indicate that a resident may have fallen, even if the resident 

is unable to press the alarm button.

Note: 

For UL 2560 installations, refer to the 

EN6080 Area Control Gateway 

Installation Instructions

 or the 

EN6040-T Network Coordinator with 

Transformer Installation Instructions

.

1.1 Inovonics Contact Information

If you have any problems with this procedure, contact Inovonics technical 

services:

• E-mail: [email protected].
• Phone: 1.800.782.2709, option 2.

1.2 Maximum Number of Repeaters for a UL 2560 

Installation

To achieve the 99.99% alarm message reliability required for UL 2560 

compliance, system installations must operate within the following limits for 

end device and repeater counts.

1.3 Pendant Components

 Figure 1  

Pendant components

2 Installation and Startup

2.1 Installation Notes

• These products are designed to be maintained by professional 

technicians.

• Products are intended for indoor use.
• Do not ship the pendant with the coin cell battery installed when 

temperatures are below 32°F. Doing so will damage the internal 

battery and cause the pendant to irretrievably fail.

• All products should be manually tested weekly (see section 6, “Test 

the Transmitter”).

2.2 Coin Cell Battery Installation

Caution: 

If you are installing batteries in multiple devices, keep the 

batteries from coming into contact with each other to prevent discharge.

1.

Place the battery in the battery compartment, ensuring that the positive 

terminal (+) faces up.

2.

Seat the battery door over the battery so that the arrow on the battery 

door is lined up with the unlocked padlock icon.

 Figure 2  

Battery door in the unlocked position

3.

Use the ACC680 alarm clearance card or a quarter to turn the battery 

door to line up the arrow on the battery door with the arrow under the 

locked padlock icon.

 Figure 3  

Battery door in the locked position

4.

Press the activation button for at least one second.

• The red LED will flash and the pendant will vibrate, indicating that an 

alarm has been sent. (For more information, see section 3.1, “Send a 

Resident-Initiated Alarm” on page 2.)

5.

Clear the alarm sent when you activated the pendant per section 3.3, 

“Clear an Alarm”.

2.3 Register the Transmitter

The transmitter sends a check-in message to the receiver or gateway every 

60 minutes for the purposes of supervision. The transmitter must be 

registered and supervised.

Caution: 

The EN2222S-60 fall detect pendant must have a supervision 

window of no more than 12 hours to avoid not discovering a missing device 

within 24 hours.
Each transmitter has a unique factory-programmed identification number. 

Refer to the receiver or gateway's installation instructions for details on 

registering and setting up supervision.

1.

When prompted by the receiver or gateway to reset transmitter, press 

the activation button, and then clear the alarm per section 3.3, “Clear an 

Alarm”.

Caution: 

The transmitter should be tested after registration to ensure 

operation. See section 6, “Test the Transmitter”.

For product and installation videos visit us at 

www.inovonics.com/videos or use the QR 

code below.

End Devices

Maximum 

Repeaters

150

397

250

386

350

375

500

360

1000

313

2000

238

3000

184

A

Activation button

B

Transmit and alarm clear 

LED

C

Low battery LED

D

Vented battery 

door

E

Attachment loop

B

C

A

D

E

Unlocked 

position

Locked 

position