EN1941 Family One-Way Binary RF Module
Installation and Operation Manual
1 Overview
EchoStream RF modules are designed to be easily interfaced with your
electronic remote application controller (RAC), allowing the assimilation of
any user-specific application into an EchoStream system. Once integrated
with existing products, RF modules provide you with complete EchoStream
functionality.
One-way binary RF modules are end-devices that use a logic-level
connection to interface with your RAC.
Figure 1
One-way system components
The one-way binary RF module is available in the following configurations:
The one-way binary RF module is available in North America, Australia and
New Zealand; the radio frequency band has been configured for the
appropriate geographic area at the factory.
Note:
For UL 2560 installations, refer to the
EN6080 Area Control Gateway
Installation Instructions
or
EN6040-T Network Coordinator Installation Instructions
.
1.1 Maximum Number of Repeaters for a UL 2560
Installation
To achieve the 99.99% alarm message reliability required for UL 2560
compliance, system installations must operate within the following limits for
end device and repeater counts.
1.2
Inovonics Wireless Contact Information
If you have any problems with this procedure, contact Inovonics Wireless
technical services:
• E-mail: [email protected].
• Phone: (800) 782-2709; (303) 939-9336.
1.3 Installation Notes
• These products are designed to be installed and maintained by
professional security technicians.
• Products are intended for indoor use.
• Manually test all products weekly.
2 One-Way Binary RF Module Components
The EN1941 is a universal one-way binary RF module with two alarm input
pins, allowing the use of dual inputs. Input one is the primary alarm, bit 0;
input two is the secondary alarm, bit 1.
Figure 2
One-way binary RF module components
N/O selection pins
Place a jumper to select normally open inputs; remove
the jumper to select normally closed.
Note:
The EN1941 is shipped with the jumper unattached. With the jumper
unattached, the EN1941 defaults to normally closed.
Secondary alarm
Connects a secondary end-device to provide RF alarm
data for any user-specific application.
Primary alarm
Connects a primary end-device to provide RF alarm data
for any user-specific application.
Tamper input
Connects a tamper input to send a message when user-
specific end-device is tampered with.
Reset input
Connects a reset input to reset the one-way binary RF module
after a frequency band selection change or N/O - N/C selection change,
and to initiate an RF transmission.
Power
Connect power cabling to an external power supply of 2.6 to 5.5
volts.
Ground
Connects to ground.
Mounting hole
Used to mount the one-way binary RF module to the user-
specific product. The mounting hole should only be used with a nylon
standoff, never metal.
LED contacts
Use to control an LED switch. Not designed to drive LED
power.
Part #
Check-In
EN1941
3 minutes
EN1941-60
60 minutes
End Devices
Maximum
Repeaters
150
397
250
386
350
375
500
360
1000
313
2000
238
3000
184
For product and installation videos visit us at
www.inovonics.com/videos or use the QR
code below.
A
N/O selection pins
B
Reserved
C
Reserved
D
Secondary alarm
E
Power
F
Ground
G
Primary alarm
H
LED contacts
I
Tamper input
J
Reset input
K
Mounting hole
B
C
G
D
I
J
E
F
A
K
H