EN1941 Family One-Way Binary RF Module

Installation and Operation Manual

1 Overview

EchoStream RF modules are designed to be easily interfaced with your 

electronic remote application controller (RAC), allowing the assimilation of 

any user-specific application into an EchoStream system. Once integrated 

with existing products, RF modules provide you with complete EchoStream 

functionality.
One-way binary RF modules are end-devices that use a logic-level 

connection to interface with your RAC.

 Figure 1  

One-way system components

The one-way binary RF module is available in the following configurations:

The one-way binary RF module is available in North America, Australia and 

New Zealand; the radio frequency band has been configured for the 

appropriate geographic area at the factory.

Note: 

For UL 2560 installations, refer to the 

EN6080 Area Control Gateway 

Installation Instructions

 or 

EN6040-T Network Coordinator Installation Instructions

.

1.1 Maximum Number of Repeaters for a UL 2560 

Installation

To achieve the 99.99% alarm message reliability required for UL 2560 

compliance, system installations must operate within the following limits for 

end device and repeater counts.

1.2 

Inovonics Wireless Contact Information

If you have any problems with this procedure, contact Inovonics Wireless 

technical services:

• E-mail: [email protected].
• Phone: (800) 782-2709; (303) 939-9336.

1.3 Installation Notes

• These products are designed to be installed and maintained by 

professional security technicians.

• Products are intended for indoor use.
• Manually test all products weekly.

2 One-Way Binary RF Module Components

The EN1941 is a universal one-way binary RF module with two alarm input 

pins, allowing the use of dual inputs. Input one is the primary alarm, bit 0; 

input two is the secondary alarm, bit 1.

 Figure 2  

One-way binary RF module components

N/O selection pins 

Place a jumper to select normally open inputs; remove 

the jumper to select normally closed.

Note: 

The EN1941 is shipped with the jumper unattached. With the jumper 

unattached, the EN1941 defaults to normally closed.

Secondary alarm 

Connects a secondary end-device to provide RF alarm 

data for any user-specific application.

Primary alarm 

Connects a primary end-device to provide RF alarm data 

for any user-specific application.

Tamper input 

Connects a tamper input to send a message when user-

specific end-device is tampered with.

Reset input 

Connects a reset input to reset the one-way binary RF module 

after a frequency band selection change or N/O - N/C selection change, 

and to initiate an RF transmission.

Power 

Connect power cabling to an external power supply of 2.6 to 5.5 

volts. 

Ground 

Connects to ground.

Mounting hole 

Used to mount the one-way binary RF module to the user-

specific product. The mounting hole should only be used with a nylon 

standoff, never metal.

LED contacts 

Use to control an LED switch. Not designed to drive LED 

power.

Part #

Check-In

EN1941

3 minutes

EN1941-60

60 minutes

End Devices

Maximum 

Repeaters

150

397

250

386

350

375

500

360

1000

313

2000

238

3000

184

For product and installation videos visit us at 

www.inovonics.com/videos or use the QR 

code below.

A

N/O selection pins

B

Reserved

C

Reserved

D

Secondary alarm

E

Power

F

Ground

G

Primary alarm

H

LED contacts

I

Tamper input

J

Reset input

K

Mounting hole

B

C

G

D

I

J

E
F

A

K

H