8/28/18 05606E © Inovonics, 2018 - www.inovonics.com

EN1224 Multiple Condition Pendant/
EN1224-ON Multiple Condition On/Off 
Pendant

Installation Instructions

1 Overview

The EN1224 multiple-condition pendant can send up to ten 

conditions; the EN1224-ON multiple condition on/off pendant has 

the buttons configured for on/off applications.

1.1 Inovonics Contact Information

If you have any problems with this procedure, contact Inovonics 

technical services:

• E-mail: [email protected].

• Phone: (800) 782-2709; (303) 939-9336.

1.2 EN1224/EN1224-ON Components

 Figure 1  

EN1224/EN1224-ON components

1.3 What’s in the Carton

• One multiple condition pendant or multiple condition on/off 

pendant.

• One 3.0V lithium battery

2 Installation and Startup

2.1 Install/Replace the Battery

1.

Pry the housing apart at either end and pull the two halves 

apart.

2.

If replacing a battery, remove the old battery.

3.

Install the new battery.

4.

Press the reset button to initialize the pendant.

2.2 Select the Frequency Band

EchoStream products are able to use a range of radio frequencies, 

and must be configured for your geographic area. This product 

ships with a default frequency range of 902-928 MHz for use in 

North America. If you are using the product in North America, skip 

to section 2.3, “Register the Pendant”; if you are using the product 

in Australia or New Zealand, you will need to configure the pendant.

5.

Place a selection jumper on the appropriate frequency band 

selection pins.

• Leave the jumper off the pins to set the frequency range to 

902-928 MHz for North America.

• Place the jumper on the bottom two pins, marked NZ, to set 

the frequency range to 921-928 MHz for New Zealand.

• Place the jumper on the top two pins, marked AU, to set the 

frequency range to 915-928 MHz for Australia.

6.

Press the reset button to complete configuration.

Caution: 

When pressing the reset button, make sure you don’t also 

touch the frequency band selection pins. Touching the frequency 

band selection pins while pressing the reset button can 

inadvertently set the pendant to the wrong frequency band.

2.3 Register the Pendant

The pendant must be registered with the system in order to be 

monitored and supervised. The pendant will send a check-in 

message to the RF gateway every three minutes. Each pendant 

has a unique factory-programmed identification number. Refer to 

the control panel’s installation instructions for details on registering 

a pendant.

1.

When prompted to reset the pendant, press and release the 

reset button.

2.

Replace the cover.

3 Operation

Caution: 

The EchoStream system should be tested regularly to 

ensure operation. To test the system, activate each of the pendant’s 

conditions and ensure an appropriate response.

3.1 Activating Conditions

The pendant can send up to ten conditions. The conditions will 

depend on the application, as will the response. The application 

controller must be designed to recognize simultaneous messages.

Condition signals are transmitted multiple times and are indicated 

by the blinking transmission LED. Inovonics recommends you test 

the pendant regularly.

For product and installation videos visit us at 

www.inovonics.com/videos or use the QR 

code below.

A

Reset button

B

Frequency band selection pins

C

Battery

B

A

C

Printing Instructions

1.

Print Duplex

2.

Align and orient back page to match front 

page.