Inovonics EN1216 Скачать руководство пользователя страница 1

8/22/19 357-05181-02 Rev A © Inovonics, 2019 - www.inovonics.com

EN1216 Dual Input Universal with Wall 

Tamper

Installation Instructions

1 Overview

The Inovonics EN1216 dual input universal with wall tamper is 

designed to be used with any standard contact or sensor. 

Inovonics multi-function add-on receivers will support both inputs 

as separate devices.

The dual input universal with wall tamper is available in North 

America, Australia and New Zealand; the radio frequency band 

has been configured for the appropriate geographic area at the 

factory.

Note: 

The EN1216 requires use of a serial receiver or network 

coordinator, as well as an application designed to support 

advanced functionality.

1.1 Inovonics Contact Information

If you have any problems with this procedure, contact Inovonics 

Wireless technical services:

• E-mail: [email protected].

• Phone: (800) 782-2709.

1.2 Dual Input with Wall Tamper Internal 

Components

 Figure 1  

Dual input with wall tamper internal components

1.3 What’s In The Carton

• Two wall mount screws.

• Two wall mount anchors.

• Two selection jumpers.

• One 3.0V lithium battery.

2 Installation and Startup

2.1 Installation Notes

• These products are designed to be installed and maintained 

by professional security technicians.

• Products are intended for indoor use.

• Manually test all products weekly.

2.2 Install the Battery

1.

Use your thumb to press the housing release tab on the 

bottom of the transmitter; separate the housing.

2.

Install the battery.

3.

Press the reset button to initialize the transmitter.

2.3 Connect Input Wiring

The transmitter has a three-terminal contact block that can 

connect inputs from one or two external contact loops. The 

middle terminal is a ground, which is shared by both contact 

loops. Input one can be configured for either a normally open or 

a normally closed contact loop using the NO/NC selection pins; 

input two is always normally closed.

1.

Connect wiring for the inputs you will be using.

2.

If you are not using input two, connect wiring between the 

input terminal and the ground terminal to set it for normally 

closed.

2.4 Select Input Type

The N/O-N/C selection pins allow the choice of a normally open 

or normally closed state for the contact circuit wired to the input 

one terminal.

The terminal is shipped set for normally closed, with no selection 

jumper on the N/O selections pins.

1.

Place a selection jumper on the selection pins to select 

normally open; remove the selection jumper from the 

selection pins to select normally closed.

2.

Press the reset button to complete configuration.

2.5 Register the EN1216

Transmitters must be registered with the system in order to be 

monitored and supervised. When supervised, the transmitter will 

send a check-in message to the receiver every three minutes. 

Each transmitter has a unique factory-programmed identification 

number.

The EN1216 includes a back tamper switch. The tamper 

condition must be defined within the control panel as a trouble 

condition when the system is disarmed, and as an alarm 

condition when the system is armed.

Refer to the receiver installation instructions for details on 

registering a transmitter.

1.

When prompted by the receiver to reset transmitter, press 

the reset button.

2.

Replace the cover.

Caution: 

The dual input universal with wall tamper should be 

tested after registration to ensure operation. To test the 

transmitter, activate each of the conditions and ensure an 

appropriate response.

2.6 Mount the EN1216

1.

Route the external wiring through the wall, as shown in 

Figure 2.

2.

Mount the transmitter to the wall using the wall-mount screw 

holes, ensuring the housing is flush against the wall and the 

wall tamper switch is firmly depressed.

 Figure 2  

Mount the transmitter to the wall

3.

Close the housing.

4.

Secure the housing through the enclosed housing screw 

hole. Accessing this screw on an active transmitter requires 

opening the housing, causing a tamper condition.

For product and installation videos visit us at 

www.inovonics.com/videos or use the QR 

code below.

A

Wall-mount screw holes 

B

N/O - N/C selection pins

C

Input one terminal

D

Ground terminal

E

Input two terminal 

F

Reset button 

G

Combined housing/wall tamper 

switch

H

Housing closure screw hole

G

B

C

F

A

A

H

D

E

Wall Tamper 

Switch

Отзывы: