Inovonics EE1941 Скачать руководство пользователя страница 1

5.25.17 06287I © Inovonics, 2017 - www.inovonics.com

EE1941/EN1941/EN1941-60 One-Way Binary 
RF Module

Installation and Operation Manual

1 Overview

EchoStream RF modules are designed to be easily interfaced with your 
electronic remote application controller (RAC). RF modules allow the 
assimilation of any user-specific application into an EchoStream system. 
Once integrated with existing products, RF modules provide you with 
complete EchoStream functionality.
One-way binary RF modules are end-devices that use a logic-level 
connection to interface with your RAC. E*1941 one-way binary RF modules 
can be used in either one-way or two-way EchoStream systems.

 Figure 1  

One-Way System Components

Note: 

For UL 2560 installations, refer to the 

EN6080 Area Control Gateway 

Installation Instructions

 or 

EN6040-T Network Coordinator Installation Instructions

.

1.1 Maximum Number of Repeaters for a UL 2560 
Installation

To achieve the 99.99% alarm message reliability required for UL 2560 
compliance, system installations must operate within the following limits for 
end device and repeater counts.

1.2 

Inovonics Wireless Contact Information

If you have any problems with this procedure, contact Inovonics Wireless 
technical services:

• E-mail: [email protected].
• Phone: (800) 782-2709; (303) 939-9336.

1.3 Installation Notes

• These products are designed to be installed and maintained by 

professional security technicians.

• Products are intended for indoor use.
• Manually test all products weekly.

2 One-Way Binary RF Module Components

The E*1941 is a universal one-way binary RF module with two alarm input 
pins, allowing the use of dual inputs. Input one is the primary alarm, bit 0; 
input two is the secondary alarm, bit 1.
There are two models in the E*1941 product family.

• The EN1941 and EN1941-60, for 900 MHz applications in North 

America, New Zealand, and Australia.

• The EE1941, for 868 MHz applications in Europe.

 Figure 2  

One-Way Binary RF Module Components

 Figure 3  

EE1941 One-Way Binary RF Module Components

Frequency band selection pins (EN1941 and EN1941-60 only) Place a 
jumper to select the frequency band for your geographic area.

• Place the jumper on the left two pins to select 915-928 MHz for 

Australia.

• Place the jumper on the right two pins to select 921-928 MHz for New 

Zealand.

• Leave the jumper off the pins to select 902-928 MHz for North 

America.

ES selection pins (EE1941 only) To enable compatibility with ES products, 
place a selection jumper on the ES selection pins; if no ES products are 
used in your system, remove the selection jumper.
N/O selection pins Place a jumper to select normally open inputs; remove 
the jumper to select normally closed.

End Devices

Maximum 
Repeaters

150

397

250

386

350

375

500

360

1000

313

2000

238

3000

184

For product and installation videos visit us at 
www.inovonics.com/videos or use the QR 
code below.

A

Board stabilization hole.

B

Reserved

C

Reserved

D

Secondary alarm

E

Power

F

Ground

G

Primary alarm

H

LED contacts

I

Tamper input

J

Reset input

K

Frequency band 
selection pins

L

N/O selection pins

M

Mounting hole

N

On-board antenna

O

Board stabilization 
hole

A

Board stabilization hole.

B

Reserved

C

Reserved

D

Secondary alarm

E

Power

F

Ground

G

Primary alarm

H

LED contacts

I

Tamper input

J

Reset input

K

ES selection pins

L

N/O selection pins

M

Mounting hole

N

On-board antenna

O

Board stabilization 
hole

B

C

G

D

I

J

E
F

K

L

M

N

H

A

O

B

C

G

D

I

J

E
F

K

L

M

N

H

A

O

Содержание EE1941

Страница 1: ...the use of dual inputs Input one is the primary alarm bit 0 input two is the secondary alarm bit 1 There are two models in the E 1941 product family The EN1941 and EN1941 60 for 900 MHz applications in North America New Zealand and Australia The EE1941 for 868 MHz applications in Europe Figure 2 One Way Binary RF Module Components Figure 3 EE1941 One Way Binary RF Module Components Frequency band ...

Страница 2: ... antenna to prevent interference I One way binary RF modules should not be mounted on metal surfaces or inside metal enclosures They should also not be mounted where sheet metal ductwork wire mesh screens etc might block transmissions J The RF module should be integrated so the antenna is unobstructed by the end user s PCB batteries or any other conductive material Figure 5 The RF module should be...

Страница 3: ...ry RF module has received a Limited Modular Grant requiring Inovonics to retain control of the final installation to ensure compliance to FCC IC regulations The integrator is responsible to test the final installation to verify compliance to FCC IC regulation for unintentional emissions Changes or modifications not expressly approved by the party responsible for compliance could void the user s au...

Страница 4: ...5 25 17 06287I Inovonics 2017 www inovonics com 4 11 US Patent Numbers 7 154 866 7 554 932 7 746 804 Other patents pending ...

Страница 5: ...scription of the final installation with attached photographs as necessary The unintentional radiator test report indicating compliance Integrator information Inovonics contact information Inovonics ATTN Product Management 397 South Taylor Ave Louisville CO 80027 Phone 303 939 9336 Toll Free 800 782 2709 Fax 303 939 8977 productmanagers inovonics com First name Last name Phone number Email address...

Страница 6: ...duct sample review and test as necessary Inovonics approval First name Last name Phone number Email address Approval status pass fail samples required compliance testing required compliance test report required Approval comments Submitted materials Returned materials Authorized signature Approval date ...

Отзывы: