![Inovance SV660P Series Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/inovance/sv660p-series/sv660p-series_hardware-manual_2064768096.webp)
‑95‑
No.
Description
⑦
Ground the motor enclosure.
Note: The main circuit terminal layout varies with different models and is subject to the
physical product.
Multi-drive grounding
Side‑by‑side installation of multiple drives:
Table 3–17 Multi‑drive grounding
No.
Description
①
Connect the main circuit input PE terminal to the grounding copper busbar of
the control cabinet through the protective grounding conductor.
②
Connect the PE cable on the input power supply end to the grounding copper
busbar of the control cabinet.
③
Connect the grounding copper busbar of the control cabinet to the metal
enclosure of the control cabinet through the protective grounding conductor.
④
Connect the motor output cable shield to the output PE terminal of the drive.
Cabinet system grounding
The most effective measure to suppress disturbance inside the cabinet is to isolate
the disturbance source from the disturbed devices during installation. Divide the
control cabinet into several EMC areas or several cabinets based on the intensity of
Содержание SV660P Series
Страница 1: ...SV660P Series Servo Drive Hardware Guide Data code 19011391 A00...
Страница 55: ...Installation 54 Figure 2 21 Installing the ferrite clamp...
Страница 66: ...Wiring 65 3 3 2 Wiring Diagram for Torque Control Mode Figure 3 5 Wiring in the torque control mode...
Страница 111: ...Wiring 110 Open collector mode For use of the internal 24 V power supply of the servo drive...
Страница 113: ...Wiring 112 Scheme 2 Using the external resistor...
Страница 135: ...Wiring 134 Selecting the regenerative resistor Figure 3 48 Flowchart for selecting the regenerative resistor...
Страница 144: ...Maintenance 143...