‑29‑
No.
Name
3
Cushion
4
Carton box
2.1.2 Installation Environment
Table 2–2 Environment requirement
Item
Requirement
Installation
location
Indoors
Grid
overvoltage
Overvoltage Category III (OVC III)
Altitude
The maximum altitude is 5000 m.
●
For altitudes not higher than 1000 m, derating is not required.
●
For altitudes above 1000 m, derate 1% for every additional 100 m.
●
For altitudes above 2000 m, contact Inovance.
Temperature
●
Mounting/Operating temperature: 0℃ to 55℃
For temperatures between 0℃ to 45℃, derating is not required. For
temperatures above 45℃, derate 2% for every additional 1℃.
●
Storage/Transportation temperature: ‑40℃ to +70℃
●
To improve the reliability of the machine, use the servo drive in
environments without dramatic temperature change.
●
When installing the servo drive into an enclosed environment such
as a control cabinet, use a cooling fan or air conditioner to keep the
temperature of the inlet air below 45℃. Failure to comply will
result in over‑temperature or a fire.
●
Install the servo drive on the surface of an incombustible object
and leave sufficient surrounding space for heat dissipation.
●
Take measures to prevent the servo drive from being frozen.
Ambient
humidity
Below 90% RH (without condensation)
Storage
humidity
Below 90%RH (without condensation)
Vibration
Below 4.9 m/s
2
●
During transportation with packing box: compliant with EN 60721‑
3‑2 Class 2M3
●
During installation without packing box: compliant with ISTA 1H
Impact
Below 19.6 m/s
2
Содержание SV660P Series
Страница 1: ...SV660P Series Servo Drive Hardware Guide Data code 19011391 A00...
Страница 55: ...Installation 54 Figure 2 21 Installing the ferrite clamp...
Страница 66: ...Wiring 65 3 3 2 Wiring Diagram for Torque Control Mode Figure 3 5 Wiring in the torque control mode...
Страница 111: ...Wiring 110 Open collector mode For use of the internal 24 V power supply of the servo drive...
Страница 113: ...Wiring 112 Scheme 2 Using the external resistor...
Страница 135: ...Wiring 134 Selecting the regenerative resistor Figure 3 48 Flowchart for selecting the regenerative resistor...
Страница 144: ...Maintenance 143...