The OnTime clock requires these settings to properly display local time: 

Setting 

Description 

Applies to… 

Digital  Analog 

Time Server 

Establishes a network time server so 
that the clock knows with which 
computer to synchronize its time. 

 

 

Time Zone 

 

Sets the local time zone so that the 
clock can display the correct local 
time. 

 

 

Daylight Savings 
Time (DST) 

Sets the DST rule so that the clock 
can automatically adapt to local 
DST. 

 

 

24-hour 

Sets a 12- or 24-hour time display.  
The factory default is 12 hour time.   

 

No effect 

Show/hide 
colon 

Determines whether the colon is 
shown on the display.  The factory 
default is to show a colon as a 
separator between hours and 
minutes.   

 

No effect

 

Table 4:  DHCP Configuration Options

 

 

The recommended practice is to load the configuration string into the DHCP 
Server and then try it with one clock by re-booting the clock.  Once you are 
confident that the one clock is properly configured using these settings, you can 
then plug in additional clocks to add them to the network, knowing that they 
will automatically receive the proper configuration settings as well. 

Note

:  A clock must be re-booted to request a new configuration string from the 

DHCP Server. The clock 

does not

 automatically request a new configuration 

string at the expiration of the DHCP lease interval. 

 

Table 5 describes the five options that can be used in a configuration string when 
establishing a private DHCP Server option for automatically configuring the 
clock. The format used is 

option name=option value

, with the options separated 

by semicolons in the configuration string.  This string is added to the DHCP 

Содержание OnTime 4-Digit Digital Clocks

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...plate for 4 Digit Clocks 13 Figure 12 Template for 6 Digit Clocks 14 Figure 13 Data Cable Installation 15 Figure 14 Clock Flush Mount Assembly 15 Figure 15 Power Up Sequence 16 Table 1 Technical Speci...

Страница 6: ...both data and power over one set of wires simplifies installation saves space and eliminates the need for electrical outlets at the clock mounting locations Additionally the option of centralized Unin...

Страница 7: ...or electrical wiring in wet locations unless the equipment is specifically designed for that purpose Be sure that mounting hardware is suitable for the mounting surface and sufficient to support the w...

Страница 8: ...eel Accuracy 1 Second 0 200 milliseconds 0 200 milliseconds Power Consumption PoE IEEE 802 3af compliant 3W actual consumption PoE IEEE 802 3af compliant 8W actual consumption PoE IEEE 802 3af complia...

Страница 9: ...er in compliance with IEEE 802 3af PoE power is commonly used to power devices such as wireless Access Points and IP telephones it is usually injected into the LAN using either PoE enabled Ethernet sw...

Страница 10: ...e power from a PoE enabled switch that conforms to the IEEE 802 3af standard If the site plan calls for a significant number of clocks to be powered from a single piece of network equipment it may be...

Страница 11: ...her PoE enabled Ethernet switches or Mid Span power injectors Consult with your IT Group to make sure that the required PoE equipment is in place The following is a recommended procedure for surface m...

Страница 12: ...Mounting Template 1 Determine mounting location There should be a solid stud or post for mounting the junction box 2 Cut a 4 1 8 x 4 104 7mm x 101 6mm hole in the drywall See Figure 3 Figure 3 Analog...

Страница 13: ...Figure 4 6 Attach the adapter plate to the junction box using the 4 screws part 3 in Figure 4 provided 7 Route the cable through the holes in the housing and then through the washers part 5 in Figure...

Страница 14: ...ure for surface mounting the digital clock No mounting kit is required 1 Determine the clock mounting location 2 Mark two points 10 25 4 cm apart which are level and centered on the data cable outlet...

Страница 15: ...7 Mounting Template for 6 Digit Clocks 3 Insert two flat head fasteners suitable for the wall surface at the marked points and tighten 4 Withdraw the fasteners until there is a 1 16 16cm gap between t...

Страница 16: ...the mounting kit with two suitable locknuts and a length of 1 9 cm pipe or conduit 2 Mark the location where the clock assembly is to be mounted making sure that the mounting means is located beneath...

Страница 17: ...8 wrench Make sure that the two washers are fitted between the Clock Mount and the Cantilever Wall Mount Refer to Figure 10 Figure 10 Digital Clock Mounting Kits 4 Insert 10 to 12 inches 30 cm of dat...

Страница 18: ...n appropriately sized opening into the wall Refer to Table 2 for appropriate dimensions for the opening Model Vertical Dimension Horizontal Dimension 4 Digit 12 3 8 or 31 4 cm 6 or 16 5 cm 6 Digit 17...

Страница 19: ...4 Drill two 5 16 holes 5 Once holes for the bolts have been made install 6 molly anchors in the holes tighten until they expand and then withdraw the screws 6 Cut out the shaded area indicated on the...

Страница 20: ...Figure 14 Figure 14 Clock Flush Mount Assembly Once the installation is complete power up the units by connecting them to a PoE enabled Ethernet LAN Both the analog and digital clocks will follow the...

Страница 21: ...Figure 15 Power Up Sequence...

Страница 22: ...u can confirm or change on a clock you should concentrate on four configuration items initially These include An IP address so that the clock can communicate on the network A network time server so th...

Страница 23: ...telnet commands Section 7 The third method is to assign an IP address and individual configuration options via a telnet session Use telnet commands to assign both a static IP address and the appropria...

Страница 24: ...This means that DHCP servers will not pre assign them in the way that options in the range of 1 to 223 are pre assigned i e Option 3 Router Private options are intended for whatever site specific use...

Страница 25: ...tions The recommended practice is to load the configuration string into the DHCP Server and then try it with one clock by re booting the clock Once you are confident that the one clock is properly con...

Страница 26: ...cation Daylight Saving Time dst command Establishes the Daylight Saving Time rule none Disable the Daylight Saving Time adjustment Other values are parsed based on the DST rule format The format is 8...

Страница 27: ...one 5 dst 1 8 2 2 1 1 10 2 Sets the time server to IP Address 10 1 128 1 Enables the colon display and sets the clock to 24 hour mode Sets the time zone to Eastern Standard Time 5 Enables DST for US 2...

Страница 28: ...ntp inovasolutions com Time Zone 5 DST Rule 1 8 2 2 1 1 10 2 Notes A clock must be re booted to request a new configuration string from the DHCP Server The clock does not automatically request a new...

Страница 29: ...r the DHCP served IP Address If an IP Address appears use this address in the steps below If the letters dhcp remain on the display then either temporarily move the clock to a network segment with DHC...

Страница 30: ...y Default Static IP Address The factory default is DHCP Refer to Section 6 for more information on DHCP Refer to Appendix A for help changing from a Static IP Address to DHCP Note Your IT staff must a...

Страница 31: ...as easy as possible Inova recommends that you record the IP Address for each clock in a table similar to the one below particularly if you have elected to set a static IP Address Clock Name or Locatio...

Страница 32: ...Host Name or IP Address of the time server 5 Press the Enter key It is always a good idea to test the synchronization between the clock and the time server To do that perform these steps 1 At the pro...

Страница 33: ...ing daylight saving time DST Setting Command No Daylight Saving Time Type the command to disable DST dst none Press the Enter key In the U S and Canada Type dst rule 1 8 2 2 1 1 10 2 Press the Enter k...

Страница 34: ...fy the Time Zone and Daylight Saving Time settings For Digital Clocks check if the Service Light is illuminated see below For Analog Clocks check the time on the small rear display The Analog Clock se...

Страница 35: ...s Verify that time appears on the display Determine the IP Address of a Clock Lift up gently on the unit to free the keyholes at the rear of the clock from the mounting hardware Disconnect the network...

Страница 36: ...ental or consequential damages from the sale or use of this product This disclaimer applies both during and after the term of the warranty Inova Solutions disclaims liability for any implied warrantie...

Страница 37: ...standard Host Name Unique identifier for a device on a TCP IP network For example 3rdFlrConfRm IP Address Unique identifier for a device on a TCP IP network For example 11 15 55 233 NTP Network Time P...

Страница 38: ...Press the Enter key European Type dst rule 1 1 2 1 1 1 9 1 Press the Enter key Other Locations The support web site at Inova OnTime Support contains a DST calculator which can compute the correct DST...

Страница 39: ...tray in the lower right corner of your screen and choose the Time Zone tab Specifying a Time Server sntp h hostname where hostname is the hostname of the time server Testing the Time Server Synchroni...

Страница 40: ...m indicator Note the space before and after p Configuring Colons On Off Note These commands are ignored by the analog clock display c off Turns off colons Note the space before and after c display c o...

Страница 41: ...e specific options that you may encounter 1 Launch the DHCP Management Console 2 Select the DHCP Server to configure 3 Choose the Action Set Predefined Options 4 Choose Add a new option 5 Set the Data...

Страница 42: ...8 Select the Option in the list and select the checkbox to enable it 9 Enter the configuration string you ve developed for your unique operating environment and geographic location...

Отзывы: