Page 45
EN
Chapter 9 Areas of application
9 Areas of application
All pumpable, powdered ready-mixed mortars can be pro-
cessed with the inoCOMB Cabrio small silo. Always follow
the manufacturer's instructions for the material!
inoCOMB Cabrio
Floor levelling compounds
P
Fire protection mortar
P
Floor levelling compounds
P
Mineral textured plasters
P
Reprofiling mortar
P
Renovating plaster systems
P
SPCC Mortar
P
SPCC filler
P
ETICS glue, mineral
P
ETICS glue, paste-like
P
Always follow the manufacturer's instructions for the material!
10 Cleaning & decommissioning
!
DANGER
Electrical voltage.
Danger of death due to electric shock.
• Work on the electronic control system may only be per-
formed by a qualified electrician.
• Switch off the machine and pull out the mains plug.
• Secure the machine against unexpectedly being switched
back on.
!
DANGER
Rotating mixing, metering and pump
shafts. Danger of death due to being pulled into the
machine and crushed.
When the motors are running, the metering shaft ro-
tates in the material hopper, the mixing shaft in the
mixing tube and the pump shaft in the pump hopper.
• Do not reach into the rotating mixing or pump shaft.
• Do not bring any objects into the rotating mixing or
pump shaft.
1. Before working on the mixing or pump shaft, disconnect
the external power supply (main switch off). Only loosen
the screw of the protective grids when the machine is
switched off.
2. Pull out the mains plug.
3. Secure the machine against unexpectedly being switched
back on.
!
DANGER
Pressurised conveyor hoses.
Risk of injury and risk of property damage due to es-
caping and/or flying material, and/or bursting con-
veyor hoses.
• Before disconnecting the conveyor hoses, make sure that
the hoses are depressurised. To do so, check the pressure
indicator on the mortar pressure gauge. The pressure in-
dicator must display 0 bar!
• Before opening the hose coupling, let the small silo ino-
COMB Cabrio run in reverse to release any pressure! To
do this, press the “Reverse pump” pushbutton until the
pressure display on the mortar pressure gauge shows 0
bar.