The transmitter is configured from a standard IBM compatible PC by

using the IPRO software version 3.05 or later. The latest version of

IPRO can be downloaded from http://www.inor.com. When the trans-

mitter is set from a PC no calibration is needed.

     The transmitter must not be connected to a computer,

when the transmitter is in hazardous area.

The transmitter is polarity protected and will not be damaged by

connecting the power supply with the wrong polarity, but the output

will be 0 mA.

The maximum load in the output loop depends on the supply voltage,

see ”DATA shortform”

The transmitter continuosly supervises the isolation resistance in

thermocouples and 3-wire-connected Pt100 including the connection

wires. If the isolation resistance is low it causes error in the

measurements and consequently a faulty ouptput. The transmitter

indicates low isolation resistance by forcing the output to a preprogram-

med value. This function requires setting by the PC-program IPRO and

the use of a temperature sensor with an extra wire.

Sensor wire check: the transmitter uses a pulsating technique to moni-

tor sensor break or sensor shortened to avoid measuring errors. This

pulsating signal may interfere with some electronic calibrators. By

selecting ”Sensor Break = None” in the IPRO software and download

the configuration into the transmitter the pulsating signal is turned off.

GENERAL INFORMATION

INTRODUCTION

IPAQ-H is a universal and intelligent 2-wire In-head transmitter for

temperature and other measurement applications.

IPAQ-HX is the Intrinsic Safe version for use in Ex-applications.

DIMENSIONS

Intelligent 2-wire

In-head Temperature

Transmitter

ATEX

CONFIGURATION

The IPAQ-H/HX transmitter must be powered, when you configure

the transmitter, (see ”Connections” fig.1). If IPRO (the IPAQ  software)

isn’t installed in your PC, install the software (follow the instructions in

”IPRO User instructions”).

For keeping the safety of the internal circuits in the

IPAQ-HX, always use Ex-power supply or a zener barrier

with limitations according to Ex-data and IPRO-X con-

figuration cable when making a configuration with the trans-

mitter in  or connected to hazardous area.

When choosing differential temperature measuments with Pt100 be

sure to select ”sensor break” = none.

Configuration from PC is ”on-line”, that is, the transmitter can be

configured while in operation if the area is known to be non-hazardous.

The output is frozen while transmission from PC to IPAQ take place.

When transfer is done the transmitter uses the new parameters.

ADDRESS

1860 Renaissance Blvd.,

Sturtevant, WI 53177

 USA

PHONE

Domestic 1-888-430-INOR

(262) 884-4535

Interna1-262-884-4535

FAX

Domestic (262) 884-4537

Interna1-262-884-4537

E-MAIL

[email protected]

ADDRESS

PO Box 9125

S-200 39 MALMÖ

 Sweden

PHONE

Domestic 040-31 25 60

Interna46-40-31 25 60

FAX

Domestic 040-31 25 70

Interna46-40-31 25 70

E-MAIL

[email protected]

ADDRESS

Rodenbacher Chaussee 6

D-63457 Hanau-Wolfgang

Germany

PHONE

Domestic 06181-582940

Interna49-6181-582940

FAX

Domestic 06181-582944

Interna49-6181-582944

E-MAIL

[email protected]

ADDRESS

Unikkotie 13

FIN-01300 VANTAA

Finland

PHONE

Domestic 09-83850210

Interna358-9-83850210

FAX

Domestic 09-83850219

Interna358-9-83850219

E-MAIL

[email protected]

SWEDEN

GERMANY

FINLAND

USA

MEASURE OF SUCCESS

!

!

Отзывы: