distance of 3 mm) must be installed, as well as
automatic residual current switches of suitable
high sensitivity.
There should be a automate fuse between the
appliance and the network.
Voltage changes should not exceed
%10V.
Ground connections and equipotential bonding
The appliance must be connected to the ground
circuit using the terminals marked by the symbol
located next to the connection terminals.
The metal structure of all the electrical appliances
must also be connected to the ground circuit using
the terminals marked by the symbol
located next to the earth terminals (equipotential
bonding system).
If, frequency inventor is being used in the equipment,
TYPE B RCD (residual current relay) with AC/DC
sensitivity must be used before the equipment power
inlet (from the mains block terminals).
SETTING UP
Testing the electrical system
Switch on the appliance following the instructions
for use and cheek the operation of the control
devices and plate heating elements.
Test the various operating temperatures.
If necessary, consult the Troubleshooting guide to
identify the problem.
Testing the rated thermal power
Always cheek the thermal power of the appliance
after installation and following maintenance
work.
The rated thermal power is indicated in the
"Technical data" table.
TROUBLESHOOTING GUIDE
The plates do not heat up
Check the fuses.
Main power switch not ON.
Low voltage or incorrect electrical connection.
Switch faulty.
One or more plates incorrectly connected or burnt
out (replace faulty plate).
Oven heating elements do not heat up
Check the fuses.
Main power switch not ON.
Low voltage or incorrect electrical connection.
Thrermostat faulty.
Heating selecyor switch faulty.
One or more heating elements incorrectly
connected or burnt out (replace faulty heating
elements).
The temperature control is difficult or
impossible to regulate
Switch/Thermostat faulty.
One or more heating elements incorrectly
connected or burnt out (replace faulty heating
element).
REPLACEMENT OF SPARE PARTS
IMPORTANT : Before carrying out maintenance
work or repairs, disconnect the appliance from the
power supply at the isolating switch.
Replacement of cooker switch
Remove the upper control panel.
Disconnect the electrical connections from switch
Replace the switch.
Replacement of oven heating elements
Work from inside the oven.
Disconnect the heating elements from the oven
and the cable
Replace the
heating elements.
Replacement of oven switch or thermostat
Remove the control knob and the vertical control
panel.
Disconnect the electrical connections from switch
or thermostat
Replace the switch or thermostat.
USE AND MAINTENANCE
INSTRUCTIONS
WARNINGS
This appliance is intended for professional use
and must only be used by trained personnel. This
appliance is exclusively designed to cook food.
Any other use shall be deemed improper.
The use of the steak griddle on the grilles is
permitted only on the small burners.
In the event of fault, disconnect the electric
connection of the grill.
For repairs, refer to authorised service centres;
demand original spare parts only.
At first operation, the appliance should be
operated at neutral position. Thus the appliance
Содержание 9KE 24
Страница 2: ...2 7 9 KE 21 7 9 KE 11 7 9 KE 24 7 9 KE 11 S 7 9 KE 21 S...
Страница 9: ...9 1 10 Henkel Helios 4 7GF302E 9GF302E 2 DIN VDE 0100 380 400 3 50 60 H07 RN F 10...
Страница 10: ...10 1 A 2 2 5 700 3...
Страница 11: ...11 900 min max 0 0 1 1 500 C 3000 C 0 75 800 C 20 30 2 3 10...
Страница 15: ...15 7 9 KE 21S 24...
Страница 16: ...16 7 9 KE 11S...
Страница 17: ...17...