Inogen One IO-100 Скачать руководство пользователя страница 1

P

a

tient

 Manual

36892_Manual.indd   1

36892_Manual.indd   1

6/5/06   10:08:32 AM

6/5/06   10:08:32 AM

Содержание One IO-100

Страница 1: ...Patient Manual 36892_Manual indd 1 36892_Manual indd 1 6 5 06 10 08 32 AM 6 5 06 10 08 32 AM ...

Страница 2: ...36892_Manual indd 2 36892_Manual indd 2 6 5 06 10 08 52 AM 6 5 06 10 08 52 AM ...

Страница 3: ...r if you would like to request this Manual in a different language Application This Manual applies to the following Inogen Inc products Inogen One Oxygen Concentrator model IO 100 AC Power Supply model BA 101 Mobile Power Charger model BA 106 Inogen One Battery model BA 100 Satellite Conserver model SC 100 External Battery Charger model BA 103 Inogen One Carry Bag model CA 102 Inogen One Cart and ...

Страница 4: ...36892_Manual indd 4 36892_Manual indd 4 6 5 06 10 08 53 AM 6 5 06 10 08 53 AM ...

Страница 5: ...eneral Instructions 16 Additional Operating Instructions Chapter 4 25 Inogen One Oxygen Concentrator Audible and Visible Signals including Alarms Chapter 5 35 Troubleshooting 35 Inogen One Oxygen Concentrator 37 Satellite Conserver Chapter 6 39 Cleaning Care and Maintenance 39 Cannula Replacement 39 Case Cleaning 40 Filter Cleaning and Replacement 40 Regular Service and Maintenance 41 Battery Care...

Страница 6: ...36892_Manual indd 6 36892_Manual indd 6 6 5 06 10 08 53 AM 6 5 06 10 08 53 AM ...

Страница 7: ...ysician WARNING Availability of an alternate source of oxygen is required in case of power outage or mechanical failure Consult your physician for type of back up system required NOTE It is the responsibility of the patient and or provider to make back up arrangements for alternative oxygen supply when traveling Inogen assumes no liability for persons choosing not to adhere to manufacturer recomme...

Страница 8: ...ygen than the Inogen One can produce and there fore may not be suited for the Inogen One General Precautions WARNING The device produces enriched oxygen gas which accelerates combustion Do NOT ALLOW SMOKING OR OPEN FLAMES within 10 feet of this device while in use WARNING Do not submerse the Inogen One or any of the accessories in liquid Do not expose to water or precipitation Do not operate in ra...

Страница 9: ...centrator Description of the Inogen One Oxygen Concentrator Chapter 2 On Off Button Alert Alarm Light Flow Control Display Display Backlight Button Breath Detection Light Mode Button Particle Filter on front panel 2 3 36892_Manual indd 9 36892_Manual indd 9 6 5 06 10 08 56 AM 6 5 06 10 08 56 AM ...

Страница 10: ...e s breath detection alert on and off 1 Default Mode When the Inogen One is powered up the breath detection alert is disabled The display s mode indication area is empty in Default Mode 2 Breath Detection Alert Mode The Inogen One will alert with audible and visual signals for no breath detected when this mode is enabled and no breath has been de tected for 60 seconds The display s mode indication...

Страница 11: ...h on automatically turns off User Interfaces Display This screen displays information regarding flow setting power status battery life and errors Indicator Lights Colored lights indicate either a change in operating status or a condition that may need response alarm Priority by color is red yellow then green A flashing light is higher priority than non flashing Audible Signals An audible signal beep ...

Страница 12: ... Inogen One output of oxygenated air DC Power In Connection for DC power connection from the AC Power Supply or Mobile Power Charger Infrared Data Port Stored operation data can be transmitted to an external infrared communications port located within the ratings label by service personnel This feature is not intended for patient use 6 36892_Manual indd 12 36892_Manual indd 12 6 5 06 10 09 18 AM 6...

Страница 13: ... in stalled in the Inogen One and the concentrator is connected to AC power Recharging time is approximately 3 hours See information in the Battery Care and Maintenance section The battery can also be recharged using the External Battery Charger Mobile Power Charger The Mobile Power Charger enables the Inogen One to be operated in an automobile or other vehicle with a DC output or a cigarette ligh...

Страница 14: ...n feet in length or less must be used to ensure proper breath de tection and oxygen delivery Satellite Conserver The Satellite Conserver enables use up to distances of 100 feet from the Inogen One Oxygen Concentrator External Battery Charger The External Battery Charger allows you to charge additional batteries This is especially useful if you are planning an ex tended outing away from electrical ...

Страница 15: ...g provides a protective cover and shoulder strap to enable you to carry the Inogen One Pockets are provided for carrying accessories The Inogen One can be operated using battery power during transport with the Carry Bag Cart The Cart has wheels and a telescoping handle to provide easy transport of the Inogen One The Inogen One can be operated using battery power during transport Description of the...

Страница 16: ...36892_Manual indd 16 36892_Manual indd 16 6 5 06 10 10 42 AM 6 5 06 10 10 42 AM ...

Страница 17: ...es below 41ºF 5ºC or above 104ºF 40ºC for extended amounts of time CAUTION Do not obstruct air intake or exhaust when operating the device Blockage of air circulation or proximity to a heat source may lead to internal heat buildup and shutdown or damage to the concentrator CAUTION Be aware that electrical cord and or tubing on the floor could present a tripping hazard NOTE It is recommended the Ino...

Страница 18: ...gen One Battery with the handle of the battery up Press firmly to make sure the battery is in the correct position Close the battery door CAUTION The Inogen One battery acts as a secondary power supply in the event of a planned or unexpected loss of the AC or DC external power supply When operating the Inogen One from an AC or DC external power supply a properly inserted Inogen One battery should b...

Страница 19: ...d Avoid the use of electrical extension cords with the Inogen One If an extension cord must be used use an extension cord that has an Underwriters Laboratory UL Mark and a minimum wire thickness of 18 gauge Do not connect any other devices to the same extension cord NOTE When the AC Power Supply is disconnected from the AC outlet also disconnect it from the concen trator to avoid unnecessary batte...

Страница 20: ...d Please Wait will appear while the concentrator starts up The display will indicate the selected flow setting and power condition Following a brief start up sequence a warm up period up to 30 minutes will initiate During this time period the oxygen concentration is building to but may not have reached specification However the Inogen One can and should be used immediately Additional warm up time ma...

Страница 21: ...educed oxygen concentration and a system error 8 Position the nasal cannula on your face and breathe through your nose The Inogen One will sense the onset of inhalation and deliver a burst of oxygen at a precise time when you inhale The Inogen One will sense each breath and continue to deliver oxygen in this manner As your breathing rate changes the Inogen One will sense these changes and deliver ...

Страница 22: ...visory alarm Oxygen Low will inform you if oxygen concen tration drops If alarm persists contact your Equipment Provider Additional Operating Instructions Mobile Power Charger for Auto RV Boat travel To use the Inogen One while traveling in an automobile plug the Mobile Power Charger into the cigarette lighter outlet or DC outlet then plug in the Inogen One Make sure the Inogen One is secure befor...

Страница 23: ...w do one of the following Plug the Inogen One into an AC power source Replace the battery with a charged battery after turning off the Inogen One by pressing the ON OFF button Attach the Mobile Power Charger If the battery is drained charge the battery or remove it from the concentrator Leaving a deeply drained battery in the Inogen One for extended periods may cause the battery to not function pr...

Страница 24: ... concentrator not running Add 1 to 3 hours of charging time with concentrator run ning depending on flow setting NOTE When starting to charge a fully discharged battery the charging process may start and stop during the first few minutes NOTE Attempting to charge a battery while running the Inogen One in elevated temperatures may lead to a Remove Battery To Cool mes sage on the display and terminati...

Страница 25: ...u are never further from a supplemental supply of oxygen with your Inogen One than you are from a source of electric power As an illustration of Battery Run Time Management imagine a day in the life of oxygen user Mae Operating Instructions Chapter 3 Time Activity Power Source Battery Period Level 6 00 8 30 AM Wake Up Breakfast AC Power Supply 100 8 30 8 50 AM Drive to store Mobile Power Charger 1...

Страница 26: ... 50 10 30 AM Church service Battery Power 15 10 30 1 00 PM Drive back home Mobile Power Charger 55 1 00 5 00 PM Bridge game lunch with friends AC Power Supply 100 5 00 5 30 PM Get mail chat with neighbor outside Battery Power 75 5 30 6 30 PM Spontaneous dinner at neighbor s home Battery Power 25 6 30 Read watch TV before going to bed AC Power Supply 100 Assuming high power usage rate setting 4 con...

Страница 27: ...ctions in the Traveling With Your Inogen One guide Consider use of the Carry Bag and Cart for transporting the Inogen One CAUTION A change in altitude for example from sea level to mountains may affect total oxygen available to the patient Consult your physician before traveling to higher or lower altitudes to determine if your flow settings should be changed Satellite Conserver If you have a Satel...

Страница 28: ...rief beep will sound and the indicator light will come on briefly Place the Satellite Conserver in your pocket around your shoulder or neck with the provided strap or attach to your belt The light during startup indicates battery status green if the battery is good yellow when marginal red when it should be immediately replaced The light will show no light during normal operation when the conserver...

Страница 29: ...ted to others and may present a tripping hazard External Battery Charger to charge an extra battery Plug the External Battery Charger into a 110 VAC electrical outlet A solid red light indicates that it is plugged in and is ready to begin charging Charging time is approximately 3 hours Slide the battery down and then firmly press into place to ensure a good connection A flashing green light means th...

Страница 30: ...36892_Manual indd 30 36892_Manual indd 30 6 5 06 10 12 49 AM 6 5 06 10 12 49 AM ...

Страница 31: ...rror notifications Power Status Icons These icons are examples of those shown in the display s power status window when the Inogen One is operating on battery power Inogen One Oxygen Concentrator Audible and Visible Signals Audible and Visible Signals Chapter 4 Meaning Battery is empty Battery has less than 10 charge remaining This icon flashes Battery has approximately 40 to 50 charge remaining Bat...

Страница 32: ...g with charge level less than 10 Battery is charging with charge level between 60 and 70 The battery is fully charged and is charging as necessary to maintain its charge Icon The Inogen One is operating from an external power source with no battery present Meaning The breath detection alarm has been enabled Icon Mode Icons These are the icons shown in the display s mode window 26 36892_Manual indd...

Страница 33: ...Explanation The Inogen logo is displayed at startup Default display when operating on battery power X X represents the selected flow setting e g Setting 2 HH MM represents the approximate time remaining on the battery charge e g 1 45 Message Display Text Setting X or Satellite Battery HH MM Meaning The concentrator is in the standard breath detect mode and the breath detection alert is disabled Thi...

Страница 34: ... beep Condition Action Explanation Default display when operating on an external power supply and the battery is charging xx represents the percent battery charge e g 86 Default display when the battery is not charging or when the time remaining is not available from the battery Display when the concentrator is plugged in and being used to charge a battery not being used for oxygen production Mess...

Страница 35: ...ur Equipment Provider Battery power is low with less than 10 remaining Attach external power supply or power down and insert a fully charged battery Battery error has occurred Switch to a new battery or remove battery and operate concentrator using external power supply If battery error recurs with same battery stop using the battery and contact your Equipment Provider Concentrator is producing ox...

Страница 36: ...tness of breath occurs reduce activity level or change to a backup oxygen source If condition persists contact your Equipment Provider Concentrator is producing oxygen but cannot report battery status Replace battery If condition persists contact your Equipment Provider The concentrator requires servicing at the earliest convenience The concentrator is operating to speci fication and may continue t...

Страница 37: ...er is not being used Concentrator is experiencing an error but is capable of continued operation As soon as you are able Remove and re insert battery and or Check external power supply connections If condition persists contact your Equipment Provider Oxygen output concentrator is below 50 If condi tion persists switch to your backup oxygen source and contact your equipment provider to arrange for ...

Страница 38: ...er Concentrator temperature is too high and oxygen production is shutting down Ensure air intake and outlet vents have clear access and particle filter is clean If condition persists switch to a backup source of oxygen and contact your Equipment Provider Message Display Text Battery Empty Attach Plug Battery HOT Shut Down System HOT Shut Down High Priority Alerts CAUTION If you are not near the Ino...

Страница 39: ...kup source of oxygen and contact your Equipment Provider Concentrator has stopped producing oxygen and is shutting down You should 1 Note error number 2 Switch to backup oxygen source 3 Contact your Equipment Provider Message Display Text System COLD Shut Down Error Service Needed High Priority Alerts continued Audible and Visible Signals Chapter 4 33 36892_Manual indd 39 36892_Manual indd 39 6 5 ...

Страница 40: ...36892_Manual indd 40 36892_Manual indd 40 6 5 06 10 12 57 AM 6 5 06 10 12 57 AM ...

Страница 41: ...n annoyance contact your equipment provider Possible Cause Refer to Section 4 External power added plugged in or removed un plugged when con centrator is start ing up and please wait message is displayed Problem Any problem accompanied by information on concentrator display indica tor lights and or audible signals Scrambled LCD Screen Solutions to some possible issues you may encounter are describ...

Страница 42: ... concentrator Check cannula and its connection to concentrator nozzle Possible Cause Battery is dis charged or no bat tery is present Malfunction Concentrator is not powered on Cannula is not connected properly or is kinked or obstructed Problem Concentrator does not power on when On Off button is pressed No oxygen 36 36892_Manual indd 42 36892_Manual indd 42 6 5 06 10 12 57 AM 6 5 06 10 12 57 AM ...

Страница 43: ...ntact your Equipment Provider Possible Cause Inogen One is not turned on or is not set to Satellite mode Tubing or cannula is not con nected properly or is kinked or obstructed Battery is discharged or no battery is present Malfunction Problem No oxygen Cleaning Care and Maintenance Chapter 5 37 36892_Manual indd 43 36892_Manual indd 43 6 5 06 10 12 58 AM 6 5 06 10 12 58 AM ...

Страница 44: ... of electromagnetic emissions permitted by the above standards Interfer ence with such devices may be determined by turning the Inogen One off and on In such rare cases interference may be reduced or corrected by one of the following measures Reorient relocate or increase the separation between the equipment Connect the equipment into an outlet on a circuit different from that to which the other d...

Страница 45: ...fittings Case Cleaning You may clean the outside case using a cloth dampened with a mild liquid deter gent such as Dawn and water WARNING Do not submerse the Inogen One or its accessories in water or allow water to enter into the case this may lead to electrical shock and or damage CAUTION Do not use cleaning agents other than those specified in this Patient Manual Do not use alcohol ethylene chlori...

Страница 46: ...ogen One Contact your Equip ment Provider if you need additional filters Regular Service and Maintenance It is recommended that the Inogen One Oxygen Concentrator be serviced at least annually by a trained technician WARNING Do not disassemble the Inogen One or any of the accessories or at tempt any maintenance other than tasks described in the trouble shooting section disassembly creates a hazard ...

Страница 47: ... One continuously displays battery time remaining This displayed time is only an estimate and the actual time remaining may vary from this value Periodic Conditioning Under some conditions battery time remaining indicator may become inac curate To reduce this risk fully charge the battery then fully discharge the battery by running the concentrator on battery power no AC until the concen trator di...

Страница 48: ...ry in extreme temperatures below 4 F 20 C or above 140 F 60 C for any amount of time Battery Disposal Contact your provider for proper battery disposal Lithium ion batteries like all rechargeable batteries are recyclable and should never be incinerated Storage CAUTION Do not store your Inogen One or accessories in extreme tempera tures below 4 F 20 C or above 140 F 60 C 42 36892_Manual indd 48 368...

Страница 49: ... precaution or service procedure must be followed Disregarding a caution could lead to a minor injury or damage to equipment See Patient Manual for Instructions U S Federal Regulation Restricts this Device to Sale by Order of Physician AC Power DC Power No Smoking while device is in use No Open Flames Concentrator Satellite Conserver Do not incinerate battery Symbol WARNING CAUTION 7 43 36892_Manu...

Страница 50: ...y Type BF Applied Part Not Intended for Cardiac Application Class II Device Electrical Safety Agency Certification Logo Symbol Meaning ON OFF Button Display Backlight Button Increase Flow Setting Decrease Flow Setting Mode User Interface Label M Symbol 44 36892_Manual indd 50 36892_Manual indd 50 6 5 06 10 13 15 AM 6 5 06 10 13 15 AM ...

Страница 51: ...36892_Manual indd 51 36892_Manual indd 51 6 5 06 10 13 18 AM 6 5 06 10 13 18 AM ...

Страница 52: ... 120 Cremona Drive Suite B Goleta CA 93117 Toll Free 877 4 inogen or 877 446 6436 E mail info inogen net www inogen net www OxygeNation com PN 96 00448 00 04 B 36892_Manual indd 52 36892_Manual indd 52 6 5 06 10 13 18 AM 6 5 06 10 13 18 AM ...

Отзывы: