background image

 

 

Innovo® iP900AP   

 
 
 
 
 
 

 

 

Finger Pulse Oximeter 

 

User Manual 

 
 
 

Innovo Medical 

10101 Stafford Centre Drive Suite B 

Stafford, TX 77477 

http://www.innovo-medical.com 

Содержание iP900AP

Страница 1: ...Innovo iP900AP Finger Pulse Oximeter User Manual Innovo Medical 10101 Stafford Centre Drive Suite B Stafford TX 77477 http www innovo medical com ...

Страница 2: ......

Страница 3: ... without prior written consent of Innovo Medical All statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either expressed or implied The information in this document is subject to change without notice Innovo Medical reserves the right of final interpretation of this document Innovo is a registered trade mark o...

Страница 4: ...s Product 9 2 1 Overview 9 2 2 Working Principles 9 2 3 Intended Use 10 2 4 Product Features 11 2 5 Limitations 11 2 6 Innovative Features of the iP900AP 12 Chapter 3 Product Structure Operation Instructions and Parameter Settings 14 3 1 Schematic Structural Diagram 14 3 2 Schematic Diagram of Display 15 3 3 Operation Instructions 15 3 4 Parameter Settings 22 ...

Страница 5: ...leaning and Disinfection 28 Chapter 5 Maintenance and Troubleshooting 30 5 1 Maintenance 30 5 2 Troubleshooting 31 Chapter 6 Technical Description and Safety Type 33 6 1 Technical Specifications 33 6 2 Safety Type 37 6 3 Storage and Transportation 37 ...

Страница 6: ...fully and follow the instructions stated herein Please also check that all accessories are complete as listed in the packing list and whether any component is damaged during shipping If there is any damage and or if you have any concerns please contact Innovo Medical at cs innovogroups com or phone 1 858 888 9781 with the following information 1 Product model 2 Serial number of the product 3 Your ...

Страница 7: ...elf Only certified engineers should maintain and repair it Change the contact position between the oximeter probe and the finger periodically if your finger feels sore or is uncomfortable Stop immediately if you have broken skin or the blood circulation of your finger is affected during prolonged use This product is not designed to be used by newborn babies Seek medical care if the measured value ...

Страница 8: ...imeter to avoid potential eye damage and or blindness This pulse oximeter is not a medical device and is not intended to diagnose and or treat any medical condition or disease It is intended for non medical use by healthy people to monitor their pulse rate and blood oxygen levels It is for sports and or aviation use People who need SpO2 and pulse rate measurements because of a medical condition sh...

Страница 9: ...o bright Hence please avoid direct exposure to strong light such as beams from operating lamps or sunlight during measurement The probe of the oximeter is placed on the same arm that a blood pressure cuff arterial duct or intravenous injection is placed The user suffers from hypotension severe vascular atrophy severe anemia or low oxygen The user is in sudden cardiac arrest or shock state The user...

Страница 10: ... may pose as an entanglement or choking hazard to small children Adult supervision is required never leave children unattended with unit or lanyard Warning Do not throw the batteries into fire as that may cause an explosion Warning Do not attempt to charge the included batteries as that could cause leakage fire disaster or even explosion Dispose the used batteries in accordance to the local laws a...

Страница 11: ...void moving the oximeter from a cold to a hot and humid environment Caution Install the batteries properly before powering on the oximeter for normal use Please remove the batteries if you are not planning to use the oximeter for an extended period of time Caution Close the battery cover when the device is in use ...

Страница 12: ...7 1 3 Symbol Symbol Meaning BF type application part Caution Please refer to this manual SpO2 Symbol of oxygen saturation bpmPR Symbol of pulse rate Manufacturer information ...

Страница 13: ...ould be sent to dedicated collection points for recycling Warning A personal injury or device damage may result if the device is not used correctly Caution Important information on the proper usage of the device Attention Necessary information to protect the device against damage ...

Страница 14: ...tion and circulation The Pulse Oximeter feature herein is small portable non invasive and easy to use The user only needs to insert a finger into the chamber to measure his her SpO2 level and pulse rate 2 2 Working Principles Oxygenated blood absorbs light preferentially at 905nm near infrared light whereas deoxygenated blood absorbs light preferentially at 660nm red light A pulse oximeter works b...

Страница 15: ...bert s law and a quantitative measurement of the users oxyhemoglobin status i e Oxygen saturation level SpO2 is derived Due to the sensitivity of the pulse oximeter finger should be kept stationary during measurement It is recommended that you use this device for measurement before or after sports Do not use for continuous monitoring 2 3 Intended Use The Innovo iP900AP Finger Pulse Oximeter is a p...

Страница 16: ...wo 1 5 V AAA batteries will allow the pulse oximeter to operate for approximately 30 hours 2 5 Limitations The pulse oximeter works by measuring the amount of oxygenated hemoglobin in your blood over a period of time Spot check pulse oximeter takes 1 2 readings every second and takes an average of 4 6 readings before displaying the result Hence you will have to wait at least 4 6 seconds before a r...

Страница 17: ...an lead to low or restricted blood flow Nail polish can also impede the pulse oximeter from taking a reading Finally it is generally accepted that the saturation percentage is unreliable on the steep part around 60 mm Hg of the oxyhemoglobin dissociation curve 2 6 Innovative Features of the iP900AP The iP900AP is designed to address and alleviate some of the above problems by 1 Increasing the sens...

Страница 18: ...iscomfort to user s finger 4 Using solid ABS plastic to block ambient light from reaching the sensor so that the signal to background ratio and the accuracy of the measurement is dramatically increased 5 Adding two invaluable features the plethysmograph and the perfusion index PI that help user determine the optimal time to get an accurate and reliable reading every time See Chapter 3 3 7 about pl...

Страница 19: ...ure Operation Instructions and Parameter Settings 3 1 Schematic Structural Diagram OLED screen Power on key function key Battery cover Note The illustration in this manual may differ slightly in appearance from the actual product ...

Страница 20: ...n the OLED screen of the Oximeter in normal detection state 3 3 Operation Instructions 3 3 1 Installing the Batteries Install two AAA batteries into the battery compartment according to the indicated polarity and mount the battery cover Incorrectly installed batteries may damage the device ...

Страница 21: ...16 3 3 2 Installing the Lanyard Thread the thin end of the lanyard through the lanyard hole and thread the coarse end of the lanyard through the thin end of the lanyard and tighten the lanyard ...

Страница 22: ...ngers into the finger chamber of the pulse oximeter Note The fingernail should be facing the top chamber which contains the sensor Finger should also be inserted completely into the chamber Otherwise measurement will be inaccurate Press the power on key to turn the pulse oximeter on ...

Страница 23: ... non toxic soft and hypoallergenic 3 3 4 Reading Oxygen Saturation Level and Pulse Rate from the OLED Screen Do not move your finger and hand during measurement Keep your body as still as possible Once the reading stabilizes read the measured values of the oxygen saturation level and pulse rate on the OLED screen ...

Страница 24: ...inger is removed from the chamber or if no signal is detected by the device 3 3 6 Switching the Display PRESS 0 5 sec the function key while in measurement mode monitoring interface to change the display layout The six different layouts are shown in the figure below Choose the layout that is the most convenient for you ...

Страница 25: ...20 Note Replace the batteries when the batteries are low and the symbol flickers on the OLED screen ...

Страница 26: ...mount of blood detected by the pulse oximeter The pulse oximeter is optimized when the height of the wave amplitude is consistent throughout as shown in the figure above That is when you should take the reading The pulse oximeter can function with a PI reading as low as 0 2 If your PI is below 0 2 this means that your blood perfusion is too low for a reliable read Warm your hands to increase blood...

Страница 27: ... pulse oximeter on Once it is turned on HOLD 0 5 sec the power on function key to enter the menu interface PRESSING 0 5 sec the power on function key will allow you to scroll through the options while HOLDING 0 5 sec will select an item indicates the option you are currently at Please see figure below 3 4 2 Alarm Setting ...

Страница 28: ...meters for Alarm the alarm will go off When Alm is set to off the alarm is deactivated The alarm will not go off regardless of your SpO2 and or PR values 3 4 3 Beep Setting To turn the beeping sound on off while measuring your pulse rate PRESS the power on key function key to move to Beep HOLD the power on key function key to switch the option from on to off or vice versa When Beep is set to on a ...

Страница 29: ...ulse oximeter to factory settings ok will be displayed 3 4 6 Brightness Setting To change brightness of the display PRESS the power on key function key to move to Brightness HOLD the power on key function key to set the brightness There are 5 brightness settings 5 is the brightest The factory default setting is 4 Please note that a brighter setting will drain the battery faster 3 4 7 Alarm Range S...

Страница 30: ...t you wish the alarm to go off at respectively To increase or decrease a value first set to or respectively Move to Then HOLD the power on key function key to set the option to or While in mode select the corresponding upper or lower limit option and hold the power on key function key to increase the upper or lower limit in mode hold the power on key function key to decrease the upper or lower lim...

Страница 31: ...t Please keep fingernails short while using the device 4 Excessive ambient infra red light especially in an overly bright lit room can interfere with the sensor preventing an accurate measurement 5 Poor blood circulation can affect oximeter readings Warm your hands and fingers before taking measurements Note that the pulse oximeter is measuring your SpO2 and PR based on your blood flow If the bloo...

Страница 32: ... If the height of the pulse bar is less than 30 this indicates signal inadequacy and the displayed SpO2 or pulse rate value is potentially incorrect Adjust your finger so that it is directly between the LED lights and sensor If the wave amplitude of the plethysmograph is very small or if the PI reading is below 0 2 warm your hands to increase blood flow and retake your measurement If the waveform ...

Страница 33: ...ened with water To disinfect use a soft cloth lightly dampened with isopropyl alcohol 1 Make sure that the device is off and remove the batteries 2 Wipe the outer surface of the device including the OLED screen and the finger chamber using lightly dampened soft cloth 3 Allow the device to air dry thoroughly before use Caution Do not use any strong dissolving agent such as acetone ...

Страница 34: ...etal objects Caution Do not immerse or soak any part of the device in any liquid Caution Do not pour or spray liquid onto the device Caution Do not allow any liquid to seep into the device during cleaning Caution Do not disinfect the device using high temperature and or high pressure disinfecting gas ...

Страница 35: ...s if they are low on power Clean the pulse oximeter and the fingertip before every use to ensure accurate reading Store the pulse oximeter between 14 F and 122 F 10 C and 50 C and at humidity levels no greater than 93 Periodically check the pulse oximeter for damage Do not use the pulse oximeter in an environment with flammable gases and or where the temperature or humidity is excessively high or ...

Страница 36: ...play the blood oxygen saturation levels and or pulse rate 1 Finger is not inserted correctly 2 User s blood perfusion is too low to be measured 1 Make sure that finger is placed right in between the sensor and LED lights 2 Make sure that nothing is restricting the user s blood flow ...

Страница 37: ... weak 1 Insert finger deep into the chamber 2 Please do not move during measurement 3 Warm finger or switch finger The oximeter cannot be powered on 1 Batteries are drained 2 Batteries are incorrectly installed 3 The oximeter is damaged or defective 1 Replace the batteries 2 Please refer to section 3 3 1 for battery installation instruction 3 Please contact the distributor ...

Страница 38: ...drained 1 This is normal Just turn the oximeter on again 2 Replace the batteries Chapter 6 Technical Description and Safety Type 6 1 Technical Specifications 1 Dimensions 62 0 mm Width 37 0 mm Depth 32 0 mm Height Approximately 2 44 inch x 1 45 inch x 1 26 inch Weight 42 5 g 1 5 oz including the weight of two AAA batteries 2 Peak wavelength range of the light emitted from the probe ...

Страница 39: ...05 nm 4 Working power supply and current Internal Power Supply Two 1 5V dry batteries Working Current 30 mA 5 Normal working condition Working Temperature 5 C to 40 C 41 F to 104 F Relative Humidity 15 to 80 non condensing Atmospheric Pressure 70 kPa to 106 kPa Rated Voltage DC 3 0 V 6 Default values and alarm conditions ...

Страница 40: ...er limit 50 Alarm condition When the alarm is set to on and the measured values exceed the preset alarm parameter range the alarm will go off 7 Technical parameters Parameter Value Display range Oxygen saturation 35 to 100 Pulse rate 25 bpm to 250 bpm Resolution Oxygen saturation 1 Pulse rate 1 bpm ...

Страница 41: ...Pulse rate 2 bpm Alarm range Oxygen saturation Upper limit 50 to 100 Lower limit 50 to 100 Pulse rate Upper limit 25 bpm to 250 bpm Lower limit 25 bpm to 250 bpm Alarm error Oxygen saturation 1 of the preset value Pulse rate The greater of 10 of the preset value and 5 bpm PI Weak PI Min 0 2 ...

Страница 42: ... 2 Safety Type Anti electric shock type internal power supply device Anti electric shock degree BF type application part Running mode continuous working Waterproof grade IP22 6 3 Storage and Transportation ...

Страница 43: ...38 ...

Страница 44: ...Distributed by Innovo Medical 10101 Stafford Centre Drive Suite B Stafford TX 77477 Phone 1 858 888 9781 cs innovogroups com www innovo medical com ...

Отзывы: