Dual Mode Digital Infrared Thermometer 

Instruction Manual Ver 1.1 

 

 

 

Содержание INV-EF100

Страница 1: ...INV EF100 Dual Mode Digital Infrared Thermometer Instruction Manual Ver 1 1 ...

Страница 2: ... in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Innovo Medical reserves the right of final interpretation of this document Version 1 1 Issuing Date June 2016 To download the latest manual for the thermometer simply scan the QR code above or visit http inn...

Страница 3: ...nfancy to adulthood That is why the INV EF100 Dual Mode Digital Infrared Thermometer is designed to be BOTH an ear thermometer AND a forehead thermometer offering users the freedom to choose between two modes We recommend that you use the forehead measurement mode if your child is less than 1 yr old The eardrum measurement mode can be used when they are older and more comfortable with a foreign ob...

Страница 4: ... 2 3 Care and Cleaning 3 4 Note on Body Temperature 5 5 Product Designs 6 6 Measuring Forehead Temperature 7 7 Measuring Temperature via Eardrum 7 8 Instructions for Display and Operation 9 9 Troubleshooting 12 10 Technical Specifications 13 11 Warranty and After Sale Service 16 12 Symbols 16 ...

Страница 5: ...on Accurate and quick Utilize the latest infrared technology accurate precise and instant readings Safe and hygienic Unlike traditional thermometers there is no glass or mercury that could pose as a potential health hazard The thermometer is made up of ABS and TPR plastics an infrared sensor an infrared temperature measuring element a microcomputer controlled circuit and a LCD screen BPA and latex...

Страница 6: ...hat you have a medical problem Do not use the thermometer for purposes not specified in this User Manual Follow the instructions stated herein and operate the thermometer carefully when measuring children s temperature Do not use the thermometer if any part especially the sensor shows any sign of damage Do not attempt to repair the thermometer Please contact your distributor The thermometer is not...

Страница 7: ...eadings CAUTION Any debris and or facial oil on the sensor lens will prevent an accurate measurement Always check the sensor before use The lens should be reflective and gleaming If it looks dull and lackluster please clean the lens before use To clean the lens gently swab the surface with a cotton swab moistened with rubbing alcohol 70 Isopropyl Do not exert too much pressure as it may damage the...

Страница 8: ...curate measurements Normal body temperature is a range and varies by site Therefore measurements from forehead and eardrum should not be compared directly In general an ear temperature is usually 0 5 1 F 0 3 0 6 C higher than an oral temperature whereas a forehead temperature is usually 0 5 1 F 0 3 0 6 C lower than an oral temperature Therefore it is NORMAL to get 1 2 F 0 6 1 2 C difference betwee...

Страница 9: ... critical to know the individual s normal body temperature when he she is well Take multiple readings to obtain the normal body temperature range and note the specific body site measured for example forehead or eardrum temperature Body Site Normal Temperature Range Forehead 94 5 F 99 1 F 34 7 C 37 3 C Eardrum 96 4 F 100 4 F 35 8 C 38 0 C Mouth 95 9 F 99 5 F 35 5 C 37 5 C Armpit 94 5 F 99 1 F 34 7 ...

Страница 10: ...rature and access Menu options 5 LCD display 6 Battery cover Normal body temperature fluctuates throughout the day and is also affected by external factors The body temperature of an individual is the lowest between 2 00 a m and 4 00 a m and the highest between 2 00 p m and 8 00 p m An individual s body temperature typically changes by less than 1 C 1 8 F each day ...

Страница 11: ...ressing the F1 button at any time although it is recommended that you wait 10 seconds between readings Make sure that the forehead is free of hair and perspiration The probe cover is attached out of the box 7 Measuring Temperature via Eardrum 1 Gently remove the probe cover to reveal the ear probe 2 Insert the ear probe into the ear canal 3 Press and release the F2 button The temperature will be d...

Страница 12: ...ok deceptively clean when it is not The lens of a clean sensor should be reflective and gleaming If it looks dull and lackluster then it is dirty Please clean the lens with a cotton swab moistened with alcohol and wait 5 10 mins for the alcohol to completely evaporate before using the thermometer 2 Please use the thermometer indoor or in an environment where there is no strong air draft 3 Do not m...

Страница 13: ... temperature will be displayed on the LCD screen 2 Measurement of ear temperature Detach the probe cover Insert the ear probe into the ear canal Press and release the F2 button The temperature will be displayed on the LCD screen 3 To measure again simply press the F1 F2 button accordingly When the temperature is below 99 6 F 37 6 C 32 0 99 5 F 0 0 37 5 C there will be a long beep and a green backl...

Страница 14: ...ress and hold button F2 for 3 6 seconds and the LCD will display with the M signal blinking None Press button F2 again and the LCD will display the number 1 with the M signal After 1 second the measured temperature with the mode of measurement icon will be displayed Note that this is the latest reading To recall the next recorded reading press button F2 again The number 2 with the M signal will be...

Страница 15: ...F 40 0 C or drops below 50 0 F 10 0 C 3 short ticks and green backlit for 3 seconds LCD screen will display ErC if there is EEPROM data reading error or the calibrating process is not finished Please contact your supplier 3 short ticks and green backlit for 3 seconds Low voltage signal when the battery voltage is below2 61V 2 Please replace battery None Power Off Mode The thermometer will power of...

Страница 16: ...anty period has not expired contact the manufacturer Battery symbol displayed when thermometer powers on The battery level is low Use new batteries of the same model or specifications Er1 is displayed The ambient temperature is lower than 10 0 C 50 0 F or higher than 40 0 C 104 0 F Take a measurement under an ambient temperature between 10 0 C 50 0 F and 40 0 C 104 0 F The temperature reading is l...

Страница 17: ...gher than the typical body temperature range in the absence of a fever The thermometer probe is faulty Contact Innovo Medical 10 Technical Specifications Items Standards Model Dual mode infrared thermometer INV EF100 Applicable regulations and laws ASTM 1965 EN12470 5 GB T 19146 2010 Temperature units F C adjustable Displayed temperature range Forehead temperature mode 32 0 F 212 0 F 0 0 C 100 0 C...

Страница 18: ...erature is below the minimum measurement range LCD displays H if the measured temperature is above the maximum measurement range LCD displays Er1 if the temperature measurement circuit is abnormal faulty sensor or temperature measurement circuit or the ambient temperature exceeds 50 0 F 104 0 F 10 0 C 40 0 C LCD displays ErC if the calibration process is not completed or EEPROM data recording is a...

Страница 19: ... 0 6 F 0 3 C for 95 Error Bookmark not defined Error Bookmark not defined Among which T1 and T2 represent temperature value for thermometer under test respectively Tref represents the constant reference temperature This infrared thermometer meets requirements established in ASTM Standard E 1965 98 Full responsibility for the conformance of this product to the standard is assumed by Innovo Medical ...

Страница 20: ...roper use are not covered under warranty 12 Symbols Symbol Description The product is a Type BF device Attention Please refer to this User Guide The action expressed in words beside the symbol is prohibited Manufacturer information including its name and address Waste electrical materials should be sent to dedicated collection points for recycling Warning A personal injury or meter damage may resu...

Страница 21: ...17 Manufactured for Innovo Medical 406 Sterling Street Building 2 Camphill PA 17011 Phone 1 858 888 9781 cs innovogroups com www innovo medical com ...