background image

 

14 

 

 

6.5 Heating mode 

6.5.1. The heater will be activated by sensing the difference between setting temperature and the actual 

ambient room temperature. 

             

                       

(TA-Ts)

2

-2

Operation conditon

Heater off

Heater on

 

 

  The Electric heater operates as below:   

a.  When  TA

Ts-2

,  the  fan  motor  operates,  and  3  seconds  later,  the  heater  is  on  and 

operates  at  low  speed  within  30  seconds.  After  30  seconds,  it  will  change  to  the  setting 

speed. If the DAHT temperature checked is higher than the protection temperature, when the 

heater operating, the fan motor will be off automatically.   

b.  When TA

Ts+2

, the heater is off, and the fan motor keeps on working at setting speed. If 

the DAHT temperature checked is low than the protection temperature, and the operation 

time of fan motor is more than 15 seconds, then the fan motor will be off.   

6.5.2. The ION/TIMER/SLEEP/FOLLOW ME functions are valid at the heating mode                       

       

 

6.6 Sensor malfunction   

 

 

 

 

 

LED display 

Stand for 

AS 

Room temperature sensor error 

LO 

Sensor protection at open circuit sensor error 

HI 

Sensor protection at short circuit sensor error     

HS 

Electric heating sensor error 

ES 

Evaporator

 temperature sensor at open or short circuit 

Содержание RE05C1D1

Страница 1: ...SERVICE MANUAL RE05C1D1 RE05C1M1 RE06C1D1 RE06C1M1 RE08C1D1 RE08C1M1 RE10C1M1 RE12C1D1 RE12C1M1 ...

Страница 2: ...definitions 12 6 2 Protection function 12 6 3 Fan only mode function requirement 12 6 4 Cooling mode function requirement 13 6 5 Heating mode 14 6 6 Sensor malfunction 14 7 Installation details 15 7 1 Installation instructions 15 7 2 How to install 16 7 3 Care and cleaning 19 8 Operation characteristics 21 8 1 Cooling operation 21 8 2 Characteristic of temperature sensor 22 9 Troubleshooting 23 ...

Страница 3: ... the product There is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire of electric shock Always install a dedicated circuit and breaker Improper wiring or installation may cause fore or electric shock Use the correctly rated breaker of fuse There is risk of fire or electric shock Do not modify or extend the power cable There is risk of fi...

Страница 4: ...Do not touch operation the product with wet hands There is risk of fire or electric shock Do not place a heater or other appliance near the power cable There is risk of fire and electric shock Do not allow water to run into electric parts It may cause fire failure of the product or electric shock Do not store or use flammable gas or combustible near the product There is risk of fire or failure of ...

Страница 5: ...ower supply plug or turn off the breaker There is risk of product damage or failure or unintended operation Take care to ensure that nobody could step on or fall onto the outdoor unit This could result in personal injury and product damage CAUTION Always check for gas refrigerant leakage after installation or repair of product Low refrigerant levels may cause failure of product Install the drain h...

Страница 6: ...ays insert the filter securely Clean the filter every two weeks or more often if necessary A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage Do not insert hands or other object through air inlet or outlet while the product is operated There are sharp and moving parts that could cause personal injury Do not drink the water drained from the pr...

Страница 7: ...5 2 Function and control panel RE06C1M1 RE10C1M1 RE12C1M1 RE08C1M1 202020190176 202021190010 202021590001 ...

Страница 8: ...ay offer slightly different features The desired cool setting is selected by rotating the knob to the right to the appropriate location HI COOL has maximum cooling effect and airflow MED COOL has intermediate cooling effect and airflow LO COOL has minimum cooling effect and airflow Cool Mode Fan Mode 202021190147 ...

Страница 9: ...the knob to the left to select your choice of fan speeds for air circulation NOTE When selecting a fan speed the compressor will not run RE12C1D1 RE05C1D1 RE06C1D1 RE08C1D1 202021191063 202021190022 202021790023 ...

Страница 10: ...8 3 Dimension Mode W mm H mm D mm RE05C1D1 RE05C1M1 406 306 335 RE06C1D1 RE06C1M1 406 306 390 RE08C1D1 RE08C1M1 471 340 400 RE10C1M1 RE12C1D1 RE12C1M1 482 372 487 ...

Страница 11: ...he important components and their function in what is called the refrigeration system This will help to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle For only cooling LIQUID SIDE GAS SIDE EVAPORATOR CONDENSER COMPRESSOR CAPILIARY TUBE ...

Страница 12: ...10 5 Wiring Diagram 1 RE05C1M1 RE06C1M1 202021191021 ...

Страница 13: ...11 2 RE12C1D1 RE05C1D1 RE06C1D1 RE08C1D1 202021190003 ...

Страница 14: ...2 1 The compressor functions protection with a delay of three minutes 6 2 2 Sensor protection at open or short circuit 6 2 3 The compressor is off with a delay of five minutes 6 3 Fan only mode function requirement 6 3 1 The compressor is OFF at Fan only mode 6 3 2 The speed can t be controlled at the mode and the temperature of indoor is display on LED 6 3 3 The ION TIMER functions are valid at t...

Страница 15: ...te compressor on When TA TS compressor off When T1 TS 2 F compressor on 6 4 3 The ION TIMER SLEEP ENERGY SAVE FOLLOW ME functions are valid at the cooling mode 6 4 4 Auto defrosting function protection as below When TE is lower it means that the evaporator frosts Then the unit starts defrosting and the indoor fan keeps working at the moment When the temperature is up the unit stops defrosting TE 5...

Страница 16: ... temperature when the heater operating the fan motor will be off automatically b When TA Ts 2 the heater is off and the fan motor keeps on working at setting speed If the DAHT temperature checked is low than the protection temperature and the operation time of fan motor is more than 15 seconds then the fan motor will be off 6 5 2 The ION TIMER SLEEP FOLLOW ME functions are valid at the heating mod...

Страница 17: ... to store unit during winter or when not in use TOOLS NEEDED Phillips Screw Driver Drill If pilot holes are needed CAUTION When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils NOTE The top rail hardware and the following Fig A Fig B and Fig C are not applicable to the units more than 10000Btu h Before installing unit the top rail must be asse...

Страница 18: ...into the room A Hold the Accordion Panel in one hand and gently pull back the center to free the open end See Fig 1 B Slide the free and I section of the panel into the cabinet as shown in Fig 2A 2B 3 Slide the panel down Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet C Once the panel has been installed on the side of the cabinet make sure it si...

Страница 19: ...se the window behind the top rail of the unit 3 Extend the side panels out against the window frame Fig 6 4 Place the frame lock between the frame extensions and the window sill as shown Fig 7 Drive 3 4 19mm or 1 2 13mm locking screws through the frame lock and into the sill Fig 8 NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws FIG 5 FIG 6 ...

Страница 20: ...st remain be sure the drain holes or slots are not caulked or painted shut Accumulated Rain Water or Condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety lock Remove screws installed through frame and frame lock Close slide side panels into frame Keeping a firm grip on air conditioner raise ...

Страница 21: ...id dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure the filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean Note Never use hot water over 40 104 to clean the air filter Never attempt to operate the unit without the air filter CAUTION Clean your air conditioner occasionally to keep it looking n...

Страница 22: ...r use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or...

Страница 23: ...21 8 Operation characteristics 8 1 Cooling operation For mechanical model For remote control model ...

Страница 24: ...0 52 3 1918 1 37 1988 26 9 5507 53 3 0707 0 35 2024 27 9 1245 54 2 959 1 33 3269 28 8 7198 55 2 8442 2 31 5635 29 8 3357 56 2 7382 3 29 9058 30 7 9708 57 2 6368 4 28 3459 31 7 6241 58 2 5397 5 26 8778 32 7 2946 59 2 4468 6 25 4954 33 6 9814 60 2 3577 7 24 1932 34 6 6835 61 2 2725 8 22 5662 35 6 4002 62 2 1907 9 21 8094 36 6 1306 63 2 1124 10 20 7184 37 5 8736 64 2 0373 11 19 6891 38 5 6296 65 1 96...

Страница 25: ...e below 17 62 To defrost the coil set FAN ONLY mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Thermostat set too cold for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a Higher setting Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Dirty air filte...

Страница 26: ...OUTSIDE when unit is cooling Unit removing large quantity of moisture from humid room This is normal during excessively humid days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructed Remove obstruction Room too cold Set temperature too low Increase set te...