Dairy Vacuum
& Pulsation Tester
USER MANUAL
Part No. DR51-0060-13
For software v2.4.1
Страница 1: ...2021 innovAg 1 DairyTest Lite Dairy Vacuum Pulsation Tester USER MANUAL Part No DR51 0060 13 For software v2 4 1...
Страница 2: ...2 2021 innovAg...
Страница 3: ...ment 18 Vacuum Recorder 19 Flushing 19 Displaying vacuum recordings 20 Pulsation Measurement 21 Regulation Characteristics 24 Displaying Regulation Characteristics 26 6 Generating a report 27 7 Genera...
Страница 4: ...on Declaration of Conformity Standards to which Conformity is Declared EN 61000 4 2 EN 61000 4 3 EN 61000 6 1 EN 61000 6 2 EN 61000 6 4 IEC 61326 2013 IEC 61326 1 2012 Ed2 EU Directive 2011 65 EU EU D...
Страница 5: ...hereby declare that the equipment specified above conforms to the above Directives and Standards Braham Basser Date 18 March 2018 Director InnovAg Pty Ltd Enclosure LCD Silicone tubing Metal fittings...
Страница 6: ...ilking stall always allow for the unpredictable nature of animals During the measurements sharp needles may be used take care they do not hurt people or animals Always ask the dairy farmer about the b...
Страница 7: ...ied calibration test instrument every 12 months which can be organised by innovAg or the local distributor When calibration is due a Needs calibration warning will appear on the startup screen The war...
Страница 8: ...5 The Basics The Button There is only one button on the DairyTest Lite and it has three functions 1 Press to turn the unit on 2 From the sessions screen press and hold to turn off 3 Press to exit the...
Страница 9: ...1 innovAg 9 Setup First start up When you first turn on the DairyTest Lite the needs calibration icon may be shown indicating the date time have not been set Continue to the Setup section to set the c...
Страница 10: ...ight brightness Time to half brightness Time to sleep Time to auto power off Set date format Parlour Presets System information Vacuum units kPa or inHg Pulsation units or ms Language Setting up refer...
Страница 11: ...presets Each can be customised with pictures and pulsation alarm limits To edit select one and press setup Delete preset Edit preset Select appropriate icons related to the preset s use Memory number...
Страница 12: ...21 innovAg Save changes Alarm enabled Alarm disabled Press each setting to edit During measurement the value will be highlighted if it is outside these limits minimum maximum on off Pulsation alarm li...
Страница 13: ...Software and hardware version information Calibration date setting values Internal serial number System log debug use only Enter Feature Code screen Enter Factory Settings screen Perform Leak Test Pe...
Страница 14: ...14 2021 innovAg Force Zero 0 0 2016 11 11 1 08pm 4 min 1 min 0 0 0 0 _ _ 0 Will force the current reading on both ports to be the zero reference Remove vacuum from both ports and press...
Страница 15: ...DairyTest Lite has 5 sessions automatically labelled with the session start date parlour icon and number of stalls DTL does not store the farm farmer name with the session on the unit The farm name ca...
Страница 16: ...e not saved to the preset s template Number of pulsators stalls maximum 200 Pulsation auto advance after memory save setting Return to number screen Move to next minor increment Move to next major inc...
Страница 17: ...nits operating Vacuum at gauge Vacuum pump inlet Vacuum pump exhaust Filtered air line Vm with air inlet Vr with air inlet Vp with air inlet Spare Vacuum measurement There are 12 preset vacuum measure...
Страница 18: ...only Select the format using the button menu or tap on the data or graph screen areas The display layout is saved and used for the next measurement Data window 0 0 Pt Current measurement point Data o...
Страница 19: ...s Spare Vacuum Recorder There are 8 preset vacuum recorder measurement points 1 2 1 2 1 4 to Flushing To protect the sensors from fluid ingress when dynamic testing Vacuum Recorder automatically flush...
Страница 20: ...aph or Graph and Data Select the format using the magnifying glass button The display layout is saved and used for the next measurement Change display format Move box left Start recording Stop recordi...
Страница 21: ...d Vacuum at center of box Minimum vacuum within box Pulsation Measurement There are 2 memories per pulsator stall 8 and 8 Select stall The state of each memory is shown by Memory saved No alarms Memor...
Страница 22: ...ot already saved Delete memory if saved Graph window DairyTest Lite calculates pulsation data to ISO standards The unstable icon is shown if values have not yet settled when changing between pulsators...
Страница 23: ...ng a specific measurement will display it in large digits Pressing again will return to the data mode screen In graph mode DairyTest Lite will automatically set the time to 1 6 sec or 3 2 sec as requi...
Страница 24: ...lation Characteristics There are 4 preset regulation characteristics measurements and two memories per measurement 1 Fall off Single cluster Fall off Two clusters Attachment Single teat cup Attachment...
Страница 25: ...ster or cups 3 Wait between 5s and 15s then close the cluster or cups 4 Wait between 5s and 15s then press stop recording Current measurement Start recording Stop recording Delete recording Advisory i...
Страница 26: ...are available If any Undershoot Vacuum drop or Overshoot value is larger than 2kPa the minimum and maximum vacuum points will be marked on the graph with dark blue minimum and light blue maximum tria...
Страница 27: ...ected to a PC Open the DairyTest Lite drive and select index html The file is best viewed using the Chrome browser The opening screen shows the five sessions available Clicking on a session will gener...
Страница 28: ...9 1457 logimat xml was collected on 9th July 2019 at 14 57 8 Screen capture A copy of the current screen can be saved to a bitmap bmp image file Tap and hold anywhere in the date time display in the t...
Страница 29: ...15s If the test fails there may be a split tube or other fault inside the unit 10 Response Test The internal filters may be blocked if the Pulsation or Vacuum modes are slow to change The Response Te...
Страница 30: ...Test Lite The battery voltage and remaining capacity are displayed in the top left corner Reformat the SD card and delete data Settings are retained Flush Port 1 open valve Flush Port 2 open valve See...
Страница 31: ...Download the update file from DairyTest Lite downloads www innovag com Generally this file will appear in the Downloads folder on your system The file will be called dtl_fw_vX Y Z 0 gHHHHHHH upd XYZ r...
Страница 32: ...e replaced as soon as possible once the low battery indicator flashes to prevent unreliable readings or operation Batteries should not be left in the unit for extended periods in case of leakage Any q...
Страница 33: ...a certified original innovAg calibrator is used Forotherdefects pleasecontactthemanufacturerforfurtherinstructions innovAg Pty Ltd Unit 37 328 Reserve Rd Cheltenham VIC 3192 Australia Ph 613 9583 2832...
Страница 34: ...or ms Rate CPM MaxVac kPa or inHg Limping A B P1 A B P2 Balance BP1 BP2 B Phase drop 4kPa Stability Pulsation Rate Range 40 to 500 CPM Rate accuracy 0 5 Ratio accuracy 0 5 of calculated value Time ms...
Страница 35: ...Batteries two AA Alkaline or NiCd NiMH rechargeable cells Digital calibration with certificate supplied Re calibration service available Selectable units Vacuum kPa inHg Pulsation ratios and ms Pulsat...
Страница 36: ...r the remainder of the applicable Warranty period Repair may include the replacement of parts or components with functionally equivalent reconditioned parts or components WARRANTY PERIOD The term of t...
Страница 37: ...ights With respect to Non excludable Rights innovAg s responsibility to the Purchaser where permitted is limited to the undertakings as stated in the clause headed WHAT WE WILL DO Subject to the above...