INSTALLATION, USE AND MAINTENANCE

 

 

 

HRP DOMO 

Heat recovery high-efficiency

 

 

 

 

 

 

 

 

 

 

 

                                                  

 

 

 

HEAT RECOVERY HIGH-EFFICIENCY 

 

Содержание HRP DOMO

Страница 1: ...Capitale sociale int vers 150 000 CF P IVA 01827470228 Iscrizione REA nr 180610 Num reg Imprese TN 10656 Numero Meccanografico TN025148 www innovaenergie com Pag 1 N420231A_ManualHRP DOMO_ Rev9 EN doc...

Страница 2: ...CONSTRUCTION FEATURES 8 1 1 9 DESCRIPTION OF OPERATION 9 1 1 10 DELIVERY STATE 9 1 1 11 REQUIREMENTS FOR STARTING 9 1 1 12 REMOVAL AND DISPOSAL 9 2 INSTALLATION 11 2 1 1 INSTALLATION CONDITIONS 11 2 1...

Страница 3: ...THOD FOR USE 22 6 1 1 GENERALITY 22 6 1 2 WORKING VERSION I 22 7 MAINTENANCE 25 7 1 1 CLEANING OR REPLACING FILTERS 25 7 1 2 CLEANING THE COOLER 25 7 1 3 GENERAL CLEANING UNIT 26 8 ALARMS 27 8 1 1 GEN...

Страница 4: ...turer reserves the right to update products and manuals without any obligation to the previous update except in exceptional cases Contact the Sales Department of the manufacturer for further informati...

Страница 5: ...kly provide information necessary for the proper use of the unit Symbols on safety CAUTION Only authorized personnel It warns that the indicated operations are important to the operation of the machin...

Страница 6: ...ices It is recommended to install an earth leakage circuit breaker failure to install this device may cause shock electricity For the connection use a cable of sufficient length to cover the entire di...

Страница 7: ...n V Vertical H Horizontal 3 Control Type E advanced electronics I E S Management Card 3v 1 1 7 IDENTIFICATION The unit is identifiable through the label on the front panel of the same lower On the pac...

Страница 8: ...n speed antifreeze and manual control of the free cooling Control via digital contacts VERSION I Complete control panel management tab 4 fan speed antifreeze automatic bypass temperature probes manage...

Страница 9: ...onnection to the network and the remote control Also available with integrated bypass 1 1 10 DELIVERY STATE The supply includes Full recovery unit of fans installed inside the unit countercurrent heat...

Страница 10: ...420231A_ManualHRP DOMO_ Rev9 EN docx Do not disassemble or dispose of the product yourself The disassembly demolition disposal of the product must be performed by authorized personnel in accordance wi...

Страница 11: ...the air ducts and connections in order to perform maintenance the consistency of the ceiling wall floor where the unit will be installed must be adapted to the weight of the unit and does not cause v...

Страница 12: ...ossible noises from contact insert strips of rubber or neoprene in this case Ceiling mount Brackets for ceiling mounting VERSION V Wall mounting For mounting the unit to the wall it is necessary to in...

Страница 13: ...st condensation adhere to the following standards give a slope of at least 2 to the exhaust pipe provide for the possibility to disconnect the drain pipe for maintenance in particular in the case of c...

Страница 14: ...noise caused by installation According to the plant in which the unit must be installed it will be possible to suitably orient the four aeraulici attacks Below any possible configurations CONFIGURATI...

Страница 15: ...switch circuit breakers cables and terminal section are suitable for installed unit electrical power and which take account of the compressor inrush currents as well as the maximum attainable load TH...

Страница 16: ...tat air quality regulator Contact closed active function CHILLER Chiller generators Activation Clean Contact Hot cold activation required N CL CP Water valve battery post Contact voltage 220v REMOTE D...

Страница 17: ...s of the unit and arranged for installation on wall or outer box 502 For the connection use Shielded cable braided from 0 75 1mm to 4 conductors CNV Remote Panel Auxiliary Connections The card allows...

Страница 18: ...network is an RS485 network Use shielded cable 2 wire with a maximum length of 150m Perform a path so as to minimize the length of the leads Finish the line with a resistance of 120 in each room do no...

Страница 19: ...ircuit diagram Note Interpose a relay to 230v between the output the regulator and the input unit Connecting Regulator Air Quality CONNECTING ELECTRONIC CARD CONTROLLER HUMIDITY UMR Is provided the co...

Страница 20: ...hrough the 230v command provided on the card COMMON N CL LIVE FIXED FOR CONTROL VALVE 3 POINTS CP CONTROL ON OFF VALVE POINTS 2 3 Connection Valve Water battery post LINK GENERATOR POST OF BATTERY The...

Страница 21: ...nt the heater on the conduit of fresh air connect the heater to the mains set the temperature on the internal thermostat to 2 C The battery in any case must be installed with the lid upwards in order...

Страница 22: ...ommand to 2 points and through the clean contact Chiller that can be used to activate the generator Installation mount the battery on the conduit of placing connect to the battery in the water pipes c...

Страница 23: ...h the On Off button on the display Power On Off Unit 6 1 2 2 EDIT MODE FANS AND FUNCTION BOOSTER On the display there are the keys for the selection of the desired drive speed Whenever the speed is se...

Страница 24: ...ls SUN WINTER SNOWFLAKE SUMMER Changing Season 6 1 2 5 LOCK local lock is activated by simultaneously pressing the and keys to 3 2 of all keys confirmation is given by the display of the written bL Al...

Страница 25: ...conditions of the filters allow you can proceed to their cleaning using a vacuum cleaner or a low pressure compressor filters for extracting Vista 7 1 2 CLEANING THE COOLER the recommended to proceed...

Страница 26: ...aning of the fans the condensate drain and the internal walls of the unit These operations must be carried out only by qualified personnel installer To perform the above operations proceed as follows...

Страница 27: ...on Air flow rate or pressure insufficient helpful Filters clogged Speed Insufficient rotation Tubazioni or clogged exchanger Clean the filters Increase the speed of rotation Clean pipes or heat exchan...

Страница 28: ...heck the connection of the card connector to the fan E3 Alarm ejection probe H4 Rupture and failure of the probe reading Check the connection of the probe or replace it E5 Alarm Outside air sensor H4...

Страница 29: ...Innova S r l Pag 29 N420231A_ManualHRP DOMO_ Rev9 EN docx 9 NOTES AND INFORMATION SERVICE NOTE...

Страница 30: ...Innova S r l Pag 30 N420231A_ManualHRP DOMO_ Rev9 EN docx...

Страница 31: ...Innova S r l Pag 31 N420231A_ManualHRP DOMO_ Rev9 EN docx...

Страница 32: ...Innova S r l Pag 32 N420231A_ManualHRP DOMO_ Rev9 EN docx 09 2017 Rev 09 Technical Assistance Center The data contained herein may be modified by the manufacturer without notice...