Core IO - CR-IO-8DI
User Manual
8 Point Modbus I/O Module, 8 DI
Страница 1: ...Core IO CR IO 8DI User Manual 8 Point Modbus I O Module 8 DI...
Страница 2: ...Wiring Digital Inputs DI 5 Wiring the RS485 networks 5 Front LED panel 6 CONFIGURE I O 7 Digital Inputs 7 Pulse Counting 7 CONFIGURING THE DEVICE 9 Fixed Settings 9 DIP Switch Setting 9 Bluetooth and...
Страница 3: ...us a company with a wealth of experience in the field and are proud to present Core IO The 8DI provides 8 digital inputs As well as monitoring volt free contacts the device also allows the use of puls...
Страница 4: ...DI RS only comes with the RS485 port while the CR IO 8DI IP comes with both RS485 and IP ports Both models also come with Bluetooth on board so configuration can be achieved using an Android device an...
Страница 5: ...owledge base website How to wire an RS485 network https know innon com howtowire non optoisolated How to terminate and bias an RS485 network https know innon com bias termination rs485 network Please...
Страница 6: ...on the status of the I Os of Core IO and more general information Below are some tables that will help decode each LED behaviour DI 1 to 8 Digital Input Mode Conditions LED Status BUS and RUN LED RUN...
Страница 7: ...ly to work as pulse counting inputs The counting maximum readable frequency is 100Hz with a duty cycle of 50 and the maximum contact closed readable resistance is 50ohm When an input is configured to...
Страница 8: ...reset is activated the counts within the timed cycle will be ignored and the counter timer reset to 0 The reset will not reset this count to 0 after it has finished a timed cycle and is displaying the...
Страница 9: ...ITCH SETTING The DIP switches are used to configure the other RS485 settings and the Modbus slave address thus RS485 End Of Line EOL resistor RS485 Bias resistors Modbus Slave Address RS485 Baud Rate...
Страница 10: ...10 Core IO 8DI Manual 1 0 4 10 2021 Get help at http innon com support Learn more at http know innon com innon com The Modbus ID and baud rate DIP switches are configured as follows...
Страница 11: ...11 1 0 4 10 2021 Get help at http innon com support Learn more at http know innon com Core IO 8DI Manual innon com 11 Slave address DIP switch settings continued...
Страница 12: ...the app then check make the following settings changes Open your phone settings drag down from top press cog icon Click on Apps Select Core Settings app Press Permissions Press Camera set to Allow on...
Страница 13: ...op down arrows in the I O Mode column to select the type of input type by clicking in the respective radio button Once you make a change or number of changes the UPDATE button on the bottom right will...
Страница 14: ...dbus RTU slave communication on these models so the user can decide which one to use to connect the BEMS to Core IO The default settings of the IP port are IP address Subnet Gateway address Modbus TCP...
Страница 15: ...sters are 32 bit long unsigned registers i e two consecutive 16 bit registers combined and their byte order is sent in little endian i e Niagara Sedona Modbus driver 1032 Teltonika RTU xxx 3412 also u...
Страница 16: ...l Points Decimal Hex Name Details Stored Type Range Firmware version units Most signi cant number for rmware version e g 2 xx YES R 0 9 0 9 0 9 R R YES YES 2nd Most signi cant number for rmware versio...
Страница 17: ...4294967295 0 4294967295 0 14400 0 14400 0 1 0 1 2 3 4 5 6 7 Read digital input status by bit only digital input mode bit 0 DI 1 Read digital input status by bit only digital input mode bit 0 DI 1 32 b...
Страница 18: ...running timer pulse input mode Running timer in minutes Will reset once counter timer set reached and start again Timer duration con guration in minutes Reset command to all counted values goes back...
Страница 19: ...19 1 0 4 10 2021 Get help at http innon com support Learn more at http know innon com Core IO 8DI Manual innon com 19 TECHNICAL DATA Drawings Part number CR IO 8DI RS Part number CR IO 8DI IP...
Страница 20: ...F max 95 RH without condensation Storage 25 C to 75 C 13 F to 167 F max 95 RH without condensation Panel mounted 2x on board sliding screw holders on the back DIN rail mounting Current draw 70mA min...
Страница 21: ...cordance with the local waste disposal legislation in force Do not dispose of the product as municipal waste it must be disposed of through specialist waste disposal centres Improper use or incorrect...