Innogy eBox professional Скачать руководство пользователя страница 1

eBox professional

Instructions for use

(Generation 3.0)

Technology 

by

Содержание eBox professional

Страница 1: ...eBox professional Instructions for use Generation 3 0 Technology by ...

Страница 2: ...Instructions for use eBox professional 2 As of 09 2021 innogy Document Center Certificates ...

Страница 3: ...t might not contain the latest changes to the product s specifications or processes described herein 04 Safety information 06 Product overview 07 Clicking the eBox into the eClick 10 eBox system configuration 11 Charging process 12 Troubleshooting 14 Specifications 18 Notes 19 Imprint ...

Страница 4: ...y may cause grievous injuries and death So heed at all times the five safety rules under DIN VDE 0105 Disconnect from all power sources Lock against reactivation Verify zero voltage all poles Earth and short circuit Cover or partition off adjoining live parts Important Technically non functioning or defective charging infrastructure must not be used In addition do not use any charging infrastructu...

Страница 5: ...tions will be legible permanently The operation of the eBox requires knowledge of these instructions The device is intended exclusively for charging electric vehicles with type 2 plugs according to IEC 62196 2 with type 1 plug according to SAE J1772 2009 only possible with alternative eBox socket version and charging current control via pilot signal according to IEC 61851 1 For a device without at...

Страница 6: ...nal with attached notes for use 1 set of instructions for use with attached PUK for Bluetooth eBox professional Product details 1 Shutter 2 Socket plug compartment 3 Type plate 4 Notes for use 5 LED ring 6 Bluetooth pairing button 7 Vehicle LED 8 Authentication LED 9 eClick separate delivery ...

Страница 7: ... at the bottom right of the eClick 03 Connect the white ribbon data cable of the eBox to port 1 on the left side of the eClick Communication via LAN or SIM card can only be ensured when the black and white ribbon data cables are connected 90 3a 3b 1 6 2a 4 5 2b 1 LAN 1 RJ45 eBox communication 2a LAN 2 RJ45 deactivated 2b LAN 2 LSA Plus deactivated 3a eSmartMeter output optional 3b eSmartMeter inpu...

Страница 8: ...Be careful not to exert excessive pressure on the circle LEDs Important Make sure that the flat ribbon data cables are not trapped between the eClick and eBox when mounting the eBox 06 Please continue to hold the eBox in place with one hand Check the final position of the locking bracket it must be fully raised The enlarged detail view demonstrates the desired final position The pin on the locking...

Страница 9: ...lace and the eBox on the eClick 08 Now the eBox is mounted on the eClick Power on the eClick circuit Important Make sure that the eBox clicks correctly into the eClick The locking bracket must be in the final position The grub screws must be fully screwed in Check eBox for firm attachment Note The grub screws can only be fully screwed in when the locking bracket is inserted completely ...

Страница 10: ... for commercial use Technical commissioning and configuration must be carried out entirely by an electrician You have the option of connecting your eBox to the innogy eMobility backend or a third party backend of your choice Via innogy eMobility backend With your purchase of the innogy eOperate software service your product s system was automatically configured to your specified e mail address Ple...

Страница 11: ...your vehicle to the eBox authenticating the charging process charging your vehicle and finally disconnecting your vehicle from the eBox Please make sure to carefully stow away any firmly connected cables after use steps 1 and 2 are interchangeable 01 Connect your electric vehicle to the eBox To do this plug the cable into the eBox first Once your car is successfully connected the vehicle LED will ...

Страница 12: ...for the following reasons Overheating of the eBox The eBox automatically reduces the charging power when a temperature limit is exceeded slowing down the charging process temporarily Therefore avoid any direct sunlight on the eBox Charging issue at the vehicle Check the error display of your vehicle Authentication error Authentication LED remains on LED ring flashes red briefly Authentication via ...

Страница 13: ...ied electrician and initiate eBox replacement if necessary Faulty Bluetooth connection Bluetooth pairing button does not light up Error in Bluetooth communication between the eBox and your smartphone tablet only relevant in private eBox operation in offline mode Restart the Bluetooth connection on your smartphone tablet and on the eBox by pressing the Bluetooth pairing button Danger Device error W...

Страница 14: ...oor areas F1 Housing material Copolymer Storage temperature 30 C to 80 C Weight 3 1 kg without cable 6 4 kg with cable each without eClick and without eSmartMeter Packaging dimensions W x D x H 515 mm x 225 mm x 235 mm without cable 695 mm x 370 mm x 235 mm with cable Power consumption in standby mode 6W Certifications CE tested and confirmed by certified body UKCA Foliation Custom film with custo...

Страница 15: ...C 32A 22 kW or 16A 11 kW Alternating one phase current 230V AC 32A 7 4 kW or 16A 3 7 kW Plug assembly Without charging cable Type 2 plug assembly as defined under DIN EN 62196 2 with automatic plug locking shutter With charging cable Type 2 plug as defined under DIN EN 62196 2 plug compartment on eBox shutter Consumption measuring Electricity meter eSmartMeter optional for eClick MID compliant Eur...

Страница 16: ... private innogy software services only via WLAN or LAN Authentication Authentication Free charging smartphone app innogy eCharge app third party apps via contract charging or direct payment via epowerdirect com Plug charge ISO 15118 Yes RFID authentication Yes according to ISO 14443A Type V ISO IEC 15693 Vicinity Supported protocols MIFARE Classic 1K MIFARE Classic 4K MIFARE DESfire V1 4K MIFARE D...

Страница 17: ...e installed in sub distribution Fault current protection switch type A RCD type A 32A connection ABB F204A 40 0 03 type A 4 pole short time delay operating voltage 230 400V AC 16A connection ABB F204A 25 0 03 type A 4 pole short time delay operating voltage 230 400V AC Short circuit overload protection to be installed in sub distribution Circuit breaker 32A connection ABB S203 NA K40A rated switch...

Страница 18: ...en eClick is rated electrical protection class I Maintenance repair The eBox is a maintenance free product It does not contain any reparable parts or components Do not carry out any repair work In case of a permanent error replace the eBox Disposal The eClick and the eBox are are electrical devices These must be disposed of accordingly in compliance with EU Directive WEEE II the ElektroG of 20 Oct...

Страница 19: ...o part hereof may be edited duplicated or published in any manner purposing other than the proper use of the eBox without express written permission of innogy eMobility Solutions GmbH innogy eMobility Solutions GmbH Flamingoweg 1 44139 Dortmund Germany Head office Dortmund Germany Registered as a company at Dortmund Local Court trade register no HRB 30359 ...

Страница 20: ...Flamingoweg 1 44139 Dortmund Germany emobility innogy com innogy emobility com eMob 104 09 21 UK sales partner innogy eMobility Limited Windmill Hill Business Park Swindon SN5 6PB Great Britain Printed on certified 100 recycled paper ...