16
measured temperature value 27.0°C(TS+CD),
the controller enter the cooling state; when
measured temperature value ≤25.0°C,
cooling will stop.
6.4.1.2 Special Temperature Control
If there is no need to judge the return
difference in heating or cooling when
power on or exiting the setting state, then
it directly compare with TS. For example:
When power on or exiting the setting state,
TS=25.0°C, CD=2.0°C, HD=3.0°C. If PV
(measured temperature value) >25.0°C, it
enters the cooling state. When PV(mea-
sured temperature value) ≤25.0°C, the
cooling stops. Then return to normal
temperature control. When PV(measured
temperature value) <25.0 °C, it enter the
heating state, when PV(measured
temperature value) ≥ 25.0 °C, heating
stops, and then return to normal tempera-
ture control.