background image

11

06

 

Control Function 

Instructions

6.1 Button Operation Instructions 
6.1.1 Button Function in Normal Operation 
       Mode
       6.1.1.1 

Quickly press "    ", PV shows HD,   

      SV shows heating difference value; Short
      Press "    " again, PV shows CD, cooling
      difference value. And It will be back to the
      normal display if there is no operation for
       3 seconds or pressing the SET button.
      

6.1.1.2

  Quickly press the SET button to             

      enter the quick setting temperature setting 
      value mode, at this time, SV displays the 
      current control setting value and flashes. 
      Quickly press "    " or "     " button to increase or    
      decrease the setting value. Long press "     "            
      or "    " button to quickly increase or decr-
      ease the setting value, then press SET 
      button to confirm and exit. If there is no
      operation, it will automatically exit after 
      10 seconds and save the setting  value.
      

WIFI

WIFI

Содержание ITC-308-WIFI

Страница 1: ...ITC 308 WIFI Smart Controller Manual ...

Страница 2: ... 5 11 19 20 01CAUTION 02 Specification 03 Technical Parameters 05 Inkbird Smart APP Setting 04 Get to Know the Device 06 Control Function Instructions 07 Exception Handling 08 Technical Assistance and Warranty ...

Страница 3: ...XTENSION CORD USE ONLY IN DRY LOCATION USINGTGE LNKBIRD CONTROLLERWITHIN 10A 110V OR 230V NORMALLY LIFE OFTHE RELAY IS 100 000 TIMES IF HEATING OR COOLING SWITCHES FREQUENTLY WHEN USING SERVICE LIFE GETSHORTER PLEASE REPLACETHE OLD CONTROLLER WITH A NEW ONE ACCORDING TO SPECIFIC USING CONDITION JUSTIN CASE OF LOSS OR DAMAGE CAUSED BYTHE DAMAGED RELAY Plug n play easy to use 1 ...

Страница 4: ...nge 40 C 100 C 40 F 212 F Temperature display accuracy 0 1 Dual relay output which can connect heatingandcoolingdeviceatthesametime Support reading in Celsius or Fahrenheit Dual screen display can display test temperature and setting temperature simultaneously Temperature calibration function Delay protection for cooling High and low temperature limit alarm can be set up Probe abnormal alarm WIFI ...

Страница 5: ...of Temperature T Fahrenheit Fahrenheit Error C F 100 C 1 C F 100 C F Temperature measurement accuracy Display unit Celsius C or Fahrenheit F Ambient temperature 20 C 60 C 4 F 140 F Storage environment temperature 0 C 60 C 32 F 140 F humidity 20 80 RH Unfrozen or condensastate Warranty Contoller 2 years warranty Temperature Probe 1 year warranty 3 ...

Страница 6: ...n normal mode it displays the temperature setting value in the setting mode it displays the setting value Red Light ON Heating output is on Green Light ON Cooling output is on Green Light Blinks The controller is performing the function of compressor delay 1 2 3 8 4 5 US Sockets EU Sockets UK Sockets AU Sockets WIFI 6 7 6 7 6 7 6 7 ...

Страница 7: ...APP Setting 5 1 Download the APP Search the keyword InkbirdSmart in Appstore or Google Play or scan the following QR code to download and install the APP 5 2 Pair with your phone Open the app it will ask you to register or log in your account on the APP Select the country and enter your Mobile number or Email to finish the registration Then press 1 InkbirdSmart 5 WIFI 6 7 8 ...

Страница 8: ...ou can long press 2 seconds to reset the WIFI It will enter the Smartconfig configuration state by default You can short press to switch the Smartconfig configuration state and the AP mode If you change the WIFI state it will take about 5 seconds to display the corresponding LED symbol and state because of the WIFI module data processing 3 6 2 WIFI WIFI ...

Страница 9: ...the device is in the Smartconfig configuration state the LED symbol is flashing interval flashing 250ms Click Confirm indicator rapidly blink and then select Wi Fi network enter Wi Fi password click confirm to enter connection process The device only supports 2 4GHz Wi Fi router 7 ...

Страница 10: ...o enter device adding interface click Confirm indicator slowly blink and then select Wi Fi network enter Wi Fi password click confirm to enter connection process Press Connect now and it will go to your WLAN Setting in your smart phone select the SmartLife XXXX to directly connect to the router without putting in password Gobacktoapptoenterintotheautomatic connection interface WIFI ...

Страница 11: ...9 Click Done after adding device succeedfully and enter into device controlling interface In the temperature control mode user can set control function via APP 4 5 ...

Страница 12: ...rature Control Mode SV Temperature Setting Value Temperature Trend Diagram Menu Setting Back to Front Page Cooling Difference Value Heating Difference Value High Temperature Alarm Low Temperature Alarm Refrigeration Delay Temperature Calibration Temperature unit switch ...

Страница 13: ...eration for 3 seconds or pressing the SET button 6 1 1 2 Quickly press the SET button to enter the quick setting temperature setting value mode at this time SV displays the current control setting value and flashes Quickly press or button to increase or decrease the setting value Long press or button to quickly increase or decr ease the setting value then press SET button to confirm and exit If th...

Страница 14: ...u code TS SV shows the corresponding setting value Press SET button to scroll down the menu item and save the parameters of the previous menu item Press or button to change the current setting value If in the setting state there is no operation within 30 seconds or long press SET button for 2 seconds it will exit and save the setting state and return to normal operation mode WIFI ...

Страница 15: ... Presss SET key for over 2 second STE TS 77 0 Heating differential value STE HD 3 0 Cooling difference value STE CD 3 0 AH 212 AL 40 0 PT OMinute STE Alarm High Limit STE Alarm Low Limit STE CA 0 0 Working normally Compressor Delay Time STE CF Temperature Calibration Temperature Ubut STE 6 2 Menu Setting Flow Chart ...

Страница 16: ...TS HD Temperature Setting Value Heating Difference Value 40 0 C 100 C 40 0 F 212 F 0 3 C 15 0 C 1 0 F 30 0 F More details on 6 4 1 More details on 6 4 4 More details on 6 4 5 More details on 6 4 3 More details on 6 4 2 25 0 C 77 0 F 2 0 C 3 0 F CA CF H CD Cooling Difference Value 0 3 C 15 0 C 1 0 F 30 0 F 2 0 C 3 0 F C AH Alarm High Temperature Limit 40 0 C 100 C 40 0 F 212 F 100 C 212 F AH P Code...

Страница 17: ... Temperature Setting Value CD Cooling difference value the controller will enter the cooling state the green led is on COOING output works the green led flashes indicating that the cooling device is in the state of the Compressor delay protection When PV measured temperature TS temperature setting value the green led is off and the COOING output turns off For example setting TS 25 0 C CD 2 0 C HD ...

Страница 18: ...he setting state then it directly compare with TS For example When power on or exiting the setting state TS 25 0 C CD 2 0 C HD 3 0 C If PV measured temperature value 25 0 C it enters the cooling state When PV mea sured temperature value 25 0 C the cooling stops Then return to normal temperature control When PV measured temperature value 25 0 C it enter the heating state when PV measured temperatur...

Страница 19: ...on to turn the buzzer alarm off only When measured temperature AL low temperature alarm then it will turn off heating or cooling output AL flashes alternately with the current temperature meantime buzzer will bi bi Biii alarm until the temperature AL buzzer off and return to normal display and control Or press any button to turn the buzzer alarm off only High and low temperature limit alarm will b...

Страница 20: ...g When two adjacent of cooling starting intervals are less than the delay time it needs to operate the remain ing delay time to start the cooling Delay time will start counting from the cooling output off 6 4 4 Temperature Calibration CA When the measured temperature deviates from the standard temperature the temperature calibration function can be used to make the measured value of the instrument...

Страница 21: ... state all setting values are restored to the default setting and the buzzer gives a short beeping prompt 7 1 When the temperature sensor circuit is short circuited or open circuit fault the controller starts the probe fault mode it will close all execution states the buzzer sounds and the digital tube displays ER then press any button to eliminate the buzzer sound after the fault is removed it wi...

Страница 22: ... We will reply your emails in 24 hours from Monday through Saturday You can also visit our web site www ink bird com to find the answers of the common technical questions 8 2 Warranty INKBIRD TECH C L warrant this controller for two years temperature sensor for one year from the date of purchase when operated under normal state of disconnected the mobile APP will still show online state and the di...

Страница 23: ...t transferable against defects caused by INKBIRD s work manship or materials This warranty is limited to the repair or replacement at INKBIRD s discretion of all or part of the controller The original receipt is required for warranty purposes ...

Страница 24: ...21 ...

Отзывы: