7. Error Description 

Sensor  Error  Alarm

When  the  temperature  sensor  circuit  is  short  circuit  or  open 

circuit,  the  controller  starts  sensor  error  mode  and  closes  all  running  status,  the  buzzer 

alarm  sounds,  screen  displays  ER.  Press  any  keys  can  cancel  buzzer  alarm,  the  system 

returns to the normal working status after error is cleared. 

 

Over-temperature  Alarm

:

  When  the  measuring  temperature  exceeds  the 

temperature  measuring  range,  the  controller  starts  over-temperature  error  alarm  mode 

and closes all running status, the buzzer alarm sounds, screen displays HL. Press any keys 

can  cancel  buzzer  alarm,  the  system  returns  to  the  normal  working  status  after  the 

temperature returns to measuring range. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

Содержание ITC-1000F

Страница 1: ... No part of this document may be reproduced without prior written permission Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete however the contents of this document are subject to revision without notice Please contact Inkbird to ensure you have the latest version of this document ...

Страница 2: ...00F 12V 5 4 Keys Instruction 6 5 Key Operation Instruction 6 5 1 Check Parameter 6 5 2 Parameter Setting 6 5 3 Operating instruction 7 6 Menu Instruction 8 6 1 When the set temperature is degrees Celsius FC C 8 6 2 When the set temperature is degrees Fahrenheit FC F 8 7 Error Description 9 Sensor Error Alarm 9 Over temperature Alarm 9 8 Technical Assistance and Warranty 10 8 1 Technical Assistance...

Страница 3: ...tric shock fire or malfunction Do not use the product where subject to flammable or explosive gas Otherwise injury from explosion may occasionally occur Never disassemble modify or repair the product or touch any of the internal parts Electric Shock fire or malfunction may occasionally occur If the output relays are used past their life expectancy contact fusing or burning may occasionally occur A...

Страница 4: ...xceeds the Limit or When Sensor Error Mounting dimension Front Panel Size 75 L 34 5 W mm Mounting Size 71 L 29 W mm Product Size 75 L 34 5 W 85 D mm Sensor Length 2m include the probe Temperature Measuring Range 50 210 o F 50 o C 99 o C Resolution 0 1 o F 0 1 o C Measuring Accuracy 1 o F 50 o F 160 o F 1 o C 50 o C 70 o C Power Supply 110Vac 220Vac 50Hz 60Hz 12Vdc Power Consumption 3W Sensor NTC S...

Страница 5: ...er wire should be kept a proper distance 3 2 ITC 1000F 220V Note Strictly distinguish interface of relay sensor and power Strictly distinguish connection of sensor and power Sensor down lead and power wire should be kept a proper distance 3 3 ITC 1000F 12V Note Strictly distinguish interface of relay sensor and power Strictly distinguish connection of sensor and power Sensor down lead and power wi...

Страница 6: ...mode set indicator lamp is on screen displays the first menu code TS Press key or key to move up or down the menu item and display the menu code Press key to enter the parameter setting of current menu the parameter value starts to flash Press key or key to adjust the parameter value of current menu After the set press key to exit the parameter setting of current menu the parameter value stops to ...

Страница 7: ...ling automatically If the measuring temperature temperature set value difference set value the controller starts refrigerating the cool indicator lamp lights on and the refrigerating relay is connected When cool indicator lamp flashes indicating that the refrigerating device is under compressor delay protecting status If the measuring temperature temperature set value the cool indicator lamp turns...

Страница 8: ...utes 3munites CA Temperature Calibration Value 15 o C 15 o C 0 o C CF Fahrenheit or Celsius Setting C 6 2 When the set temperature is degrees Fahrenheit FC F Code Function Set range Default Note TS Temperature Set Value 50 210 o F 50 o F Min Unit 1 o F DS Difference Set Value 1 30 o F 3 o F PT Compressor Delay 0 10 minutes 3 minutes CA Temperature Calibration Value 15 15 o F 0 o F CF Fahrenheit or...

Страница 9: ...ays ER Press any keys can cancel buzzer alarm the system returns to the normal working status after error is cleared Over temperature Alarm When the measuring temperature exceeds the temperature measuring range the controller starts over temperature error alarm mode and closes all running status the buzzer alarm sounds screen displays HL Press any keys can cancel buzzer alarm the system returns to...

Страница 10: ...condition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty is limited to the repair or replacement at INKBIRD s discretion of all or part of the thermostat The original receipt is required for warranty purposes INKBIRD is not responsible for injury property damage or other consequential damages or damages of third parties arising...

Отзывы: