background image

 

 

 

IHC-230 User Manual

 

Inkbird Tech. Co., Ltd.                                                                        www.ink-bird.com

 

 

2. Specification 

Power Input 

100 ~240VAC, 50Hz/60Hz 

Power Output 

Max. 10A, 100V ~240V AC 

Power consumption 

<3W 

Temperature 

Controller 

Range 

-40

~100

/ -40

~212

 

Temperature Resolution 

0.1

/

 @ -40.0~99.9

/

 

1

 @ 100~212

 

Temperature Accuracy 

±0.5 

/ ±1

 

Humidity Measuring Range  0%-100%RH 

Humidity Control Range 

0%-99.9%RH 

Humidity Resolution 

0.1%RH 

Humidity Accuracy 

±3%RH 

Sensor model 

HTG3515CH 

Sensor Length 

2m / 6.56ft 

Relay Contact Capacity 

Humidity (12A, 100-240VAC) 

Temperature (12A, 100-240VAC) 

Input Power Cable Length 

1.5m ( 5ft ) 

Output Power Cable Length  30cm ( 1ft ) 

Dimension 

Main Body: 140x68x33mm (5.5x2.7x1.3 inch) 

Socket (US Version): 85x42x24mm (3.3x1.7x1.0 inch) 

Socket (EU Version): 135x54x40mm (5.3x2.1x1.6 inch) 

Socket (UK Version): 140x51x27mm (5.5x2.0x1.0 inch) 

Ambient Temperature 

-30~ 75 ° C /  -22~ 167 ° F 

Storage 

Temperature -30~ 75 ° C /  -22~ 167 ° F 

Humidity 20~85% (No Condensate ) 

Warranty 

1 Year 

 

Main Features 

 

Control up to 1200 Watts (120v)/ 2200 Watts (220v) of  Combined temperature and 

humidity control devices. 

 

Plug-n-play design, easy to use. 

 

2-in-1 remote temperature/humidity sensor with 6.5 feet cable. 

 

Temperature Controller Range: -40

~100

/ -40

~212

 

Содержание IHC-230

Страница 1: ...served No part of this document may be reproduced without prior written permission Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete however the contents of this document are subject to revision without notice Please contact Inkbird to ensure you have the latest version of this document ...

Страница 2: ...ow to Set Parameters 6 4 3 Setup Flow Chart 7 5 Menu Instruction 8 5 1 Control Range Setting 9 5 2 Humidity Temperature Control HD HS DS HC TS DS 9 5 3 Alarm Limit Setting AH AL 9 5 4 Compressor Delay PT 9 5 5 Calibration CA 10 5 6 Display in Fahrenheit or Centigrade unit CF 10 6 Error Description 10 Sensor Fault Alarm 10 7 Technical Assistance and Warranty 11 7 1 Technical Assistance 11 7 2 Warra...

Страница 3: ...oduct Doing so may occasionally result in electric shock fire or malfunction DO NOT use the product where subject to flammable or explosive gas Otherwise injury from explosion may occasionally occur DO NOT disassemble modify or repair the product or touch any of the internal parts Electric Shock fire or malfunction may occasionally occur If the output relays have been used over their life expectan...

Страница 4: ...dity 12A 100 240VAC Temperature 12A 100 240VAC Input Power Cable Length 1 5m 5ft Output Power Cable Length 30cm 1ft Dimension Main Body 140x68x33mm 5 5x2 7x1 3 inch Socket US Version 85x42x24mm 3 3x1 7x1 0 inch Socket EU Version 135x54x40mm 5 3x2 1x1 6 inch Socket UK Version 140x51x27mm 5 5x2 0x1 0 inch Ambient Temperature 30 75 C 22 167 F Storage Temperature 30 75 C 22 167 F Humidity 20 85 No Con...

Страница 5: ... Cooling and dehumidifying devices Alarm will be on when temperature or humidity exceeds high low alarm setting value 3 Keys Instruction Window 1 Temperature measuring Value or Setting Menu Code Window 2 Humidity Measuring Value or Setting value Temperature Indicator Lamp Work1 On Working Off Stop Working Flickering Delay Output Humidity Indicator Lamp Work2 On Working Off Stop Working Flickering ...

Страница 6: ...ow to Set Parameters Under running mode press and hold SET key for 3 seconds to enter parameters setting mode window1 displays the first menu code MD while window2 displays according setting value Press SET key to page down the menu then the code will display press key to change the current parameter values After finished settings press and hold key for 3 seconds at any status to save the paramete...

Страница 7: ...IHC 230 User Manual Inkbird Tech Co Ltd www ink bird com 7 4 3 Setup Flow Chart ...

Страница 8: ...y Protected Delay Only for Dehumidifying 0 10Minute 0 5 3 CA Humidity Calibration Offset 15 15 RH 0 5 4 When MD T Temperature setting mode Symbol Code Function Setting Range Default Note HC Temperature Control Mode H Heating C Cooling H 5 1 TS Temperature Set Value 40 100 40 212 25 DS Temperature Control Differential 1 20 2 AH Temperature High Limit Alarm 40 100 40 212 100 5 2 AL Temperature Low L...

Страница 9: ...midity temperature higher than AH the humidity temperature high alarm will be on when the measured humidity temperature lower than AL the humidity temperature low alarm will be on When alarm is on the display will be flashing between the measured value and alarm code with the BI BI BIII sound The alarm sound can be stopped by pressing any key but the status of alarm will be not change until the va...

Страница 10: ... degree displaying can be selected as needed Default displaying is in Centigrade degree Please set CF to F to change the displaying in Fahrenheit degree if needed Attentions After CF value changed all the setting value will be recovered to factory settings 6 Error Description Sensor Fault Alarm when sensor is being in short circuit or open loop the controller will initiate sensor fault mode by sto...

Страница 11: ...ondition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty is limited to the repair or replacement at INKBIRD s discretion of all or part of the thermostat The original receipt is required for warranty purposes INKBIRD is not responsible for injury property damage or other consequential damages or damages of third parties arising ...

Отзывы: