background image

Plug and Play Temperature Controller

ITC-306T

User Manual

Version 1.1s

Inkbird Tech. Co., Ltd.

Copyright

Copyright

©

2016 Inkbird Tech. Co., Ltd. All rights reserved. No part of this document may be reproduced

without prior written permission.

Disclaimer

Inkbird has made every effort to ensure that the information contained in this document is accurate and
complete; however, the contents of this document are subject to revision without notice. Please contact
Inkbird to ensure you have the latest version of this document.

Содержание ITC-306T

Страница 1: ...No part of this document may be reproduced without prior written permission Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete...

Страница 2: ...s 6 4 2 Setup Flow Chart 7 5 Menu Instruction 8 5 1 Temperature Control Range Setting TS DS 9 5 2 Cycle Time Setting TR TAH TAM TBH TBM CTH CTM 10 5 3 Temperature Calibration CA 10 5 4 Display in Fahr...

Страница 3: ...isplay and offers the optional display of Centigrade or Fahrenheit which makes it more humanized temperature control With large power output 1200W 110V 2200W 220V it s suitable for most applications A...

Страница 4: ...put Max 10A 100V 240V AC Sensor Type NTC sensor Including Sensor Length 2m 6 56ft Relay Contact Capacity Heating 10A 100 240VAC Input Power Cable Length 1 5m 5ft Output Power Cable Length 30cm 1ft Dim...

Страница 5: ...ator Lamp When the light is on start heating Work2 Indicator Lamp SET key Press SET key for 3 seconds to enter menu for function setting During the setting process press SET key for 3 seconds to quit...

Страница 6: ...code TS1 while SV window displays according setting value Press SET key to go to next menu and display according menu code press key or key to set current parameter value After setting done press SET...

Страница 7: ...2 Setup Flow Chart Remarks TE error If TR 1 and it is power on again after power off The window of SV displays TE error When enter to the setting menu it will jump to TH code directly then you can set...

Страница 8: ...function is on Menu code Function Setting range Default setting Remarks TS1 Temperature Set Value 1 50 99 9 25 5 1 DS1 Heating Differential Value1 0 3 15 1 0 CA Temperature Calibration 15 15 0 5 3 CF...

Страница 9: ...lue1 1 30 2 TAH Time A setting Hour 0 24 hours 8 8 00 5 2 TAM Time A setting Minute 0 60 minutes 00 8 00 TBH Time B setting Hour 0 24 hours 18 18 00 TBM Time B setting Minute 0 60 minutes 00 18 00 CTH...

Страница 10: ...s corrected value corrected value could be positive value 0 or negative value 5 4 Display in Fahrenheit or Centigrade unit CF Users can select display with Fahrenheit or Centigrade temperature value a...

Страница 11: ...day You can also visit our web site www ink bird com to find the answers of the common technical questions 7 2 Warranty INKBIRD TECH C L warrants this thermostat for one years from the date of purchas...