3.2 Programming terminals
3.2 Programming terminals
The Flex2R/2T terminals used for connections must be programmed through the con-
trol panel in accordance with the
selected for the home-automation
module.
l
Generic home-automation module
‘T1’ and ‘T2’ terminals can be programmed as:
l
Control panel zones
l
Outputs, ‘dimmer’ and ‘relay use’ operating modes are unavailable. The interlock option is
applicable to the ‘T1’ and ‘T2’ pair when both are programmed as outputs.
l
Input/Output, or supervised output
l
Double zone
Terminals ‘SW1’ and ‘SW2’ can only be programmed as ‘relay use’ outputs. The ‘buzzer’ and ‘dimmer’
options are unavailable. The interlock option is applicable to the ‘SW1’ and ‘SW2’ pair.
l
Standard roller-shutters module
Terminals ‘T1’ and ‘T2’ are ‘technological’ zones, normally open, they belong to all partitions and
they have all other programming options at default.
Terminals ‘SW1’ and ‘SW2’ are outputs with the ‘monostable’ (monostable time 0, unpro-
grammable), ‘relay use’, ‘home automation’ and ‘interlock’ options enabled.
l
‘Smart’ roller-shutters module
Terminals ‘T1’ and ‘T2’ are ‘technological’ zones, normally open, they belong to all partitions and
they have all other programming options at default.
Terminals ‘SW1’ and ‘SW2’ are outputs with the ‘monostable’ (mono-stable time 0, unpro-
grammable), ‘relay use’, ‘home automation’ and ‘interlock’ options enabled.
l
Roller-shutters module with single ON/OFF button
Terminal ‘T1’ is a ‘technological’ zone, normally open, associated with all partitions and with all other
programming options at default.
Terminal ‘T2’ is fully customizable, as in the case of a home-automation module.
Terminals ‘SW1’ and ‘SW2’ are outputs with the ‘monostable’ (monostable time 0, unpro-
grammable), ‘relay use’, ‘home automation’ and ‘interlock’ options enabled.
l
Roller-shutters module with one long press button
Terminal ‘T1’ is a ‘technological’ zone, normally open, associated with all partitions and with all other
programming options at default.
Terminal ‘T2’ is fully customizable, as in the case of a home-automation module.
Terminals ‘SW1’ and ‘SW2’ are outputs with the ‘monostable’ (monostable time 0, unpro-
grammable), ‘relay use’, ‘home automation’ and ‘interlock’ options enabled.
l
Roller-shutters module with no buttons