Technical manual MA xxxx with ATS MAxx
©INGUN: Subject to technical changes without notice. E&OE.
50
10 T
ECHNICAL
D
ATA
10.1 Specification of components used
10.1.1 Stroke switch (Part number 20202)
Set-up of contact: 5 A 250 VAC
Release force: 0.1 N
Connection terminal type: solder
Connection
10.1.2 Inductive sensor (Part number 26466)
Type: inductive sensor
Type/design: flush
Switching display: LED yellow
Start switch setting: PNP closer (NO)
Switching frequency: 5 kHz
Operational voltage range: 10 - 30 VDC
Current consumption: 5,5 mA
Current setting: < 100 mA
Protection type: IP 67
Working temperature: -25 - +70 °C
Switching distance: 0.6 mm (Aluminium)
Connection
10.1.3 Inductive sensor M8x1 (Part number 33831)
Type: inductive sensor
Type/design: flush
Switching display: LED yellow
Start switch setting: PNP closer (NO)
Switching frequency: 1500 Hz
Operational voltage range: 10 - 32 VDC
Current consumption: 10 mA
Current setting: < 200 mA
Protection type: IP 67
Working temperature: -25 - +70 °C
Switching distance: 1.2 mm (Aluminium)
Connection
x) = Main switching circuit of
proximity sensor
10.1.4 Inductive sensor (Part number 36684)
Type: inductive sensor
Type/design: not flush
Switching display: LED yellow
Starting voltage: PNP closer (NO)
Switching frequency: 1500 Hz
Operation voltage range: 10 - 32 VDC
Current rating: 10 mA
Starting current: < 200 mA
Protection type: IP 67
Working temperature: -25 - +70 °C
Switching distance: 1.9 mm (aluminium)
Connection
x) = Main switching circuit of
proximity sensor
10.1.5 Inductive sensor (Part number 38413)
Type: inductive sensor
Switching status display: LED red
Start switching status: PNP closing
contact (NO)
Switching frequency: 5 kHz
Nominal voltage: 10 - 30 VDC
Current consumption max.: 12 mA
Output current: <200 mA
Protection category: IP 67
Working temperature: -25 - +75 °C
Nominal switching distance: 2 mm
Connection
Содержание MA 2x09 Series
Страница 1: ...Technical manual Manual Test Fixture MA xxxx with ATS MAxx...
Страница 55: ...Technical manual MA xxxx with ATS MAxx INGUN Subject to technical changes without notice E OE 54...
Страница 57: ...Technical manual MA xxxx with ATS MAxx INGUN Subject to technical changes without notice E OE 56...
Страница 58: ...Technical manual MA xxxx with ATS MAxx 57 INGUN Subject to technical changes without notice E OE...