Содержание IES5000RQ0

Страница 1: ...tions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed INSTALLATION INSTRUCTIONS Toolsand Parts Check that you hove everything necessary for correct installation Proper installation is your responsibility Flat blade screwdriver Tin snips new vent Adjustable wrench that instal...

Страница 2: ...ed in an area where it will be exposed to water and or weather Check code requirements Some codes limit or do not permit installation of the dryer in garages closets mobile homes or sleeping quarters Contact your local building inspector Installation Clearances The location must be large enough to allow the dryer door to open fully J 74 rd 1 tJ10 m I Small Opening Side Swing Door 2 Large Opening S...

Страница 3: ...er supply cord Use a UL approved power supply cord kit marked for use with clothes dryers The kit should contain A UL approved 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ringterminals or spade terminals with upturned ends A UL approved strain relief If your outlet looks lik...

Страница 4: ...een ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result In death fire or electrical shock 1 Disconnect powen 2 Remove the hold down screw and terminal block coven 2 3 4 1 Terminal block cover 2 E_temal ground connector 3 Center silver colored terminal block screw 4 Hold down screw location 5 Neutral...

Страница 5: ...erminals with upturned ends 6 _ in 1 9 cm UL approved strain relief 7 Ring terminals 1 2 Remove center terminal block screw Remove appliance ground wire green with yellow stripes from external ground connector screw Fasten it under center silver colored terminal block screw 1 2 3 1 External ground connector Dotted line shows position of NEUTRAL ground wire before being moved to center terminaJbloc...

Страница 6: ...al block screw 3 Green yallow wire of harness 3 Connect ground wire green or bare of power supply cable to external ground conductor screw nghtan screw Place the hooked end of the neutral wire white or center wire of power supply cable under the center screw of terminal block hook facing right Squeeze hooked end together nghten screw 2 3 1 4 5 6 I _ in 1 9 cm UL listed sprainrelief 2 Green or bare...

Страница 7: ...k facing right squeeze hooked end together and tighten screw 1 2 3 Loosen or remove center terminal block screw Place the hooked end of the neutral wire white or center wire of power supply cable under the center screw of terminal block hook facing right Squeeze hooked end together nghten screw 2 3 _4 1 Neutral grounding wire green yellow 2 External ground connector 3 Center silver colored termina...

Страница 8: ...r fire WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS 4 in 10 2 cm heavy metal exhaust vent and clamps must be used DURASAFE TM venting products are recommended DURASAFE TM vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories For more information see the Assistance or Service section of your Dryer User Instructions Use a heavy meta...

Страница 9: ...neath the mobile home Terminate the exhaust vent outside Determine Vent Length 1 Select the route that will provide the straightest and most direct path outdoors Plan the installation to use the fewest number of elbows end turns When using elbows or making turns allow as much room as possible Bend vent gmduellyto avoid kinking Avoid 90 turns lJ 2 Determine vent length The maximum length of the exh...

Страница 10: ...r each of the 2 dryer back corners Stand the dryer up Slide the dryer on the corner posts until it is close to its final location Leave enough room to connect the exhaust vent 6 Once connection is made end dryer is in final location remove corner posts and cardboard Level Dryer Check the levelness of the dryer Check levelness first side to side then front to back Ifthe dryer is not level prop up t...

Страница 11: ...of slots _ghtan screws Insert and tighten top sorws in hinges 10 Remove door strike plug 2 Insert the door strike you r moved in Step 8 in hole and escure with screw Insert door strike plug in original door strike hole and escure with screw 11 Close door and check that door strike aligns with door catch 3 If needed slide door catch left or right within slot to adjust alignment Complete Instolloflo...

Страница 12: ...8535914 Benton Harbor Michigan 49022 3 03 2003 All rights reserved TM DURASAFE is a trademark of Whirlpool U S A Printed in U S A ...