Access Point, when it is ready, then press the WPS button on the iGS01S device( the WPS button

needs to be pressed for over 1 sec) to join it.

Reset to Default

In case you need to go back to the original settings, keep pressing the reset/default button

in your device for over 5 secs no matter in which mode the device is. The WiFi LED will be turned

off and when you release the button, the iGS01S will reboot to its default settings(AP mode).

Firmware Upgrade

Check AP002_iGS01_Firmware_Upgrade for details.

LEDs

There are two LEDs to indicate current status like the right figure. The upper one is BLE LED and

the lower one is WiFi LED. Below are their behaviors.

On

Flash

BLE LED

find tag/beacon in range

BLE transmission happening

WiFi LED

AP mode: AP is ready for
connect
Station mode: connect to
assigned AP successfully

WiFi transmission happening

The device quickly blinking
while joining AP during boot

Create Connection

iGS01S is in Access Point(AP) mode defaultly. If you have no idea what mode currently it is in,

please press the multi-function button to reset it to the default state. In AP mode, you could scan and

connect it with the WiFi of your NB/PC/Mac/Tablet/Smartphone. It’s name is just like the above figure

with part of the mac address. The default key to connect with it is “12345678”. You can change it later

when you get into the web UI.

After connection, enter IP address 192.168.10.1 in your browser. The default account/password

are both “admin”. You can change the password later. In web UI, any change needs to be saved first.

After all changes made, click reboot to make the changes effective. When In Station mode, the IP

address of the iGS01S is assigned by the other AP. To get into the web UI, you have to find the assigned

IP address. The following sections describe details of the web UI.

INGICS TECHNOLOGY CO., LTD.    •    [email protected] •    WWW.INGICS.COM

4

Содержание iGS01S

Страница 1: ...rview Inside the box WiFi BLE Input and Output Multi function button WPS Reset to Default Firmware Upgrade LEDs Create Connection Web User Interface Wi Fi Simple AP Station Network AP Client Setting AP Server Setting Applications M2M TCP Server M2M TCP Client HTTP Client Force HTTPS Keep Alive Request Interval Throttle Control MQTT Client MQTTS Request Interval and Throttle Control please refer to...

Страница 2: ...ckage iGS01S is powered by a standard micro USB cable rated at 5V 500mA You can power this device with a standard smartphone charger or the USB port of any host device that can support 500mA or above WiFi For WiFi connection it provides two modes Access Point mode AP mode and Station mode In AP mode it acts as a simple AP supporting DHCP The main purpose of this mode is for configuration In Statio...

Страница 3: ...ld is added to the packet Check the System section for the NTP setting report type GPRP general purpose report RSPR active scan response report tag id MAC address or ID of tag beacon gateway id MAC address of gateway s BLE rssi RSSI of tag beacon raw packet content Raw packet received by the gateway unix epoch timestamp Optional timestamp when NTP is enabled Input and Output Multi function button ...

Страница 4: ...Fi transmission happening The device quickly blinking while joining AP during boot Create Connection iGS01S is in Access Point AP mode defaultly If you have no idea what mode currently it is in please press the multi function button to reset it to the default state In AP mode you could scan and connect it with the WiFi of your NB PC Mac Tablet Smartphone It s name is just like the above figure wit...

Страница 5: ... be supported by request Station Scan Click it to scan available APs Site Survey The scan result is listed here and users can choose the correct AP from the list The WiFi channel of the AP is also listed SSID No manual input required It is automatically filled once a user chooses an AP from the scan list Security Protocol Basically it is automatically detected and selected after choosing an AP fro...

Страница 6: ...to change the IP address in AP mode just set the IP and Netmask here The corresponding DHCP client address will be changed too For example if the DHCP server IP address is changed to 192 168 0 1 the DHCP clients associated with iGS01S AP will be 192 168 0 X Applications M2M TCP Server iGS01S is a TCP server with a fixed IP address 192 168 10 1 The default port is 8080 and users can also assign the...

Страница 7: ... keep alive which will improve network throughput Request Interval One can also assign the request interval to upload the data to the HTTP server This is useful and it can reduce the HTTP connections When the interval is set as 0 the data will be sent immediately When it is set as a non zero value in seconds the data will be sent whenever the buffer is full or the time interval is reached Throttle...

Страница 8: ...te key in the advanced page Request Interval and Throttle Control please refer to HTTP client Advanced There are several features in this page that can help users to deal with the incoming BLE packet BLE Filter Users can set BLE filters to filter out the unwanted BLE information There are two kinds of filters One is by BLE RSSI value and the other is by pattern mask combination RSSI If the bar is ...

Страница 9: ...is compliant with the WEEE directive for re use recovery recycling This cross out wheeled bin symbol is a reminder that this product should not be treated as household waste Instead hand it over to the appropriate collection point for the recycling of electrical and electronic equipment in accordance with local environmental regulations for waste disposal Since our product is not sold directly to ...

Страница 10: ...east 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Industry Can...

Страница 11: ...GS01S has been tested and complies with the essential requirements of the DIRECTIVE 2014 53 EU and DIRECTIVE 2014 35 EU Below is the copy of the CE Conformity of Declaration INGICS TECHNOLOGY CO LTD JK FAN INGICS COM WWW INGICS COM 11 ...

Страница 12: ... the last page June 1 2021 01b 1 Add Waste Electrical and Electronic Equipment Recycling section for appropriate recycling the equipment 2 Add Certification section 3 Fix typo and re arrange page Jun 8 2021 01c Update the content of the certification chapter INGICS TECHNOLOGY CO LTD JK FAN INGICS COM WWW INGICS COM 12 ...

Отзывы: