ACA2011IQM01_ - Installation and Operation Manual
5. Preparation for installing the unit
When deciding the location of the unit and planning your installation, you must follow a set of guidelines based on
the specifications of the unit. These guidelines are summarized in this chapter.
5.1. Environment
•
Place the units in a place that is accessible for installation and maintenance work and which allows
operating through the TFT display.
•
The air vents and part of the power module can reach high temperatures. Do not place any material
nearby which is sensitive to high air temperatures.
•
Avoid corrosive environments that may affect its proper operation. Do not install the unit in areas
classified as ATEX.
•
Never place any object on top of the unit.
•
It is recommended to place the units under a cover that protects them from direct radiation, placing the
front part facing north in the Northern Hemisphere and facing south in the Southern Hemisphere.
•
Keep the following minimum distances free of obstacles.
60 cm
70 cm
70 cm
50 cm
Minimum clearance distances
66
Preparation for installing the unit
Ingeteam
Содержание INGEREV RAPID 120
Страница 3: ...ACA2011IQM01_ Deutsch DE English EN Espa ol ES Fran ais FR Italiano IT Portugu s PT 3 Ingeteam...
Страница 44: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 84: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 124: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 164: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 204: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 244: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 245: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 246: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 248: ...ACA2011IQM01_ 08 2021 Ingeteam Power Technology S A www ingeteam com...